515 "Modular Design" AC Drive 350 - 1500 HP
|
Performance Features:
 | Ratings: 350 to 1500 HP at 460 VAC,
350 to 1500 HP at 600 VAC |
 | Overload capacity: |
 |
150% for 60 sec (200% peak) |
 | Starting torque: 150% |
 | Electronic reversing |
 | Adjustable accel/decel: 0.1 to 6000 sec |
 | Controlled speed range:
(1) 40:1,
(2) 100:1,
(3) 1000:1 |
 | Drive efficiency: 96 to 98% |
 | Displacement power factor: 0.98 |
 | Output frequency: 0.1 to 150 Hz |
 | Jog forward and reverse |
 | Power loss ride-thru: 2 sec |
 | Inertia ride-thru |
 | Selectable auto restart after momentary power loss |
 | Programmable auto restart (0 to 10 attempts) on resettable fault |
 | Critical frequency rejection: |
 |
3 selectable, adjustable bands |
Protective Features:
 | DC bus CHARGE indicator |
 | Optically-Isolated controls |
 | Phase-to-phase / phase-to-neutral short circuit protection |
 | Ground fault protection |
 | Electronic motor overload (UL)/(NEC) |
 | Current and torque limit |
 | Overtorque/undertorque detection |
 | Fault circuit: overcurrent, overvoltage, and overtemperature |
 | Input/output phase loss |
Design Features:
 |
32-bit logic, including 16-bit DSP |
 | Carrier frequency to 2 kHz |
 |
Alpha-numeric operator, removable, 2 lines x 16 character |
 |
24 VDC control logic |
 |
Programmable outputs. One form A and two open collector |
 |
Timer function |
 |
RS-232 communication port |
 |
9 Multi-speed settings |
 |
Remote speed reference:
-10 to +10 VDC (20K ohms) or
4 to 20 mA (250 ohms) |
 |
Setpoint (PID) control |
 |
Signal follower: bias and gain |
 |
Analog monitor output: -10 to +10 VDC proportional to output parameters |
 |
DC bus reactor: |
 |
Dual motor parameter sets |
 | Auto-tune to motor characteristics |
 |
Common bus capability |
 |
Programmable external faults : Oty 6 |
 |
Run and fault contacts (1 A) |
 |
Up / down / hold reference |
 |
NEMA 1 enclosed |
 | MTBF: exceeds 28 years |
 |
Output reactor (parallel output sections only) |
Vector Control Features:
 |
Speed resolution:
0.01% with digital reference
0.1% with analog reference |
 |
Speed regulation: (15 to 35 C)
(2) 0.1% with digital reference
(3) 0.01% with digital reference
(3) 0.1% analog reference |
 | (3) Encoder response: 300kHz |
 |
(3) Optional PG card, A/B/Z ph line driver,+5 or +12v |
 |
(3) Stall torque: to 150% at zero speed for 1 minute, 100% continuous |
Volts/Hertz Features:
 | DC injection braking: ramp or coast to stop, adj. current limited to 60% motor rating |
 | Frequency resolution:
0.01 Hz with digital reference
0.06 Hz with analog reference |
 | Frequency regulation (15 to 35 C): 0.01 % with digital ref ; 0.1 % with analog
ref |
 | Torque boost: full range, auto |
 | Current limited stall prevention during accel, decel and run |
 | Synchronized start into rotating motor via speed search |
 | V/Hz ratio: 15 preset; 1 infinitely-adj. |
 | Slip compensation |
Service Conditions:
 | Ambient service temperature: -10 C to 40 C (104 F) NEMA 1 |
 | Humidity: to 95% non-condensing |
 | Altitude: to 3300 ft, higher by derating |
 | Inputvoltage: +10%/-15%, 380 to 460 VAC, 500 to 600 VAC |
 | 3-phase sequence insensitive |
 | UL listed-, cUL listed; IEC: 146A |
Options:
 | Remote operator stations |
 | Pressure to electrical transducer |
 | Input circuit breaker, disconnect, fuses, |
 | NEMA 12 enclosures |
 | RS-485 communication port |
 | Isolation transformer |
 | Analog monitor, precision |
 | Digital or pulse monitor output |
 | Two additional form C contacts |
 | Dynamic braking |
 | 12 pulse transformers |
 | Upload/download software |
 | Serial communications
Industrial: Modbus, DeviceNet, Profibus
and others
Commercial: Johnson Control /
Metasys, Landis and Staefa
|
Top of Page |