GPD 506 Drive with Bypass Control
|
GPD 506 Features:
 | Ratings:
0.75 to 100 HP at 208 VAC,
0.75 to 125 HP at 230 VAC,
0.75 to 500 HP at 460 VAC,
2.0 to 200 HP at 575 VAC, (consult factory) |
 | Overload capacity: 120% for 60 sec (180% peak) |
 | 150% starting torque capability, available from 1.5 Hz. to 60 Hz |
 | DC injection braking |
 | Electronic reversing |
 | Adjustable accel/decel: 0.1 to 3600 seconds (2 each) |
 | Controlled speed range of 40:1 |
 | Critical frequency rejection: 2 adjustable bandwidths |
 | Torque limiting circuit: 30 to 180% |
 | GPD 506 efficiency: 96% at halt-speed; 98% at full-speed |
 | Energy $aving control: improves motor efficiency |
 | Displacement power factor: 0.98 |
 | Output frequency: 0.1 to 400 Hz |
 | Frequency resolution:
0.01 Hz with digital reference,
0.06 Hz with analog reference |
 | Frequency regulation:
0.01 % digital (-10 to 40 C),
0.1 % analog (15 to 35 C) |
 | Torque boost: full range, auto |
 | Jog forward and reverse |
 | Power loss ride-thru: 2 sec |
 | Inertia ride-thru |
 | Selectable auto restart after momentary power loss |
 | Programmable auto restart (0 to 10 attempts) after resettable fault |
 | DC bus reactor: 25-100 HP at 208 VAC, 30-125 HP at 230 VAC, 30-250 HP at 460 VAC |
 | Volt, ammeter, kilowatt, elapsed run time meter functions |
 | Input and output terminal status indication |
 | Diagnostic fault indication |
 | S-curve (soft start/stop) capability |
 | Loss of input signal protection, with a speed default to a programmable
percentage of the most recent speed |
 | "Up/Down" control capability |
 | Program security code |
 | 32 bit microprocessor based control circuit |
 | Programmable output contacts, one form C and one NO; selectable from 18
functions, including:
- Zero speed detection
- Low or high frequency detection
- Missing frequency reference
- Overtorque detection |
 | Five programmable input terminals; selectable from 27 functions, including:
-Remote/Local operation selection
-Detection of external overheat condition
-Preset speed selection |
 | Timer function: contact initiated |
 | Multi-speed settings: 6 available |
 | Signal follower: bias and gain |
 | The average MTBF (mean time between failure) is 28 years |
Service Conditions:
 | Ambient service temperature:
-10 C to 40 C (104 F) |
 | Ambient storage temperature:
-20 C to 60 C (140 F) |
 | 95% humidity: non-condensing |
 | Altitude: to 3300 ft, higher by derating |
 | Service factor: 1.0 |
 | Vibration: 1 G. maximum under
20 Hz; 0.2 G at 20 Hz. to 60 Hz |
C21 Style Bypass Features:
 | Factory assembled; drive and bypass circuit electrically interlocked |
 | With motor in "bypass" mode, GPD 506 can be removed for service |
 | Enclosure: NEMA 1 or "NEMA 12 Type" filtered & blowered |
 | Remote speed reference: 0 to 10 VDC or 4 to 20 mA |
 | Setpoint (PID) control w/inverse input & sleep function |
 | Damper circuit safety interlock |
 | Running on drive, running on bypass and drive or motor fault contacts |
 | Optimized package for use with communication interfaces |
 | Easily accessible terminal strip for customer connections |
 | Analog monitor output: 0 to 10 VDC |
 | Circuit breaker disconnect, with interlocked, through-the-door operating
mechanism |
 | Drive Input, Drive Output, and Bypass contactors |
 | Thermal overload relay, for motor protection in both "drive" and "bypass"
modes |
 | 115 VAC control power transformer, fused |
 | "Drive Off / Bypass" selector switch |
 | "Auto Manual" selector switch |
 | "Normal / Test" selector switch |
 | "Power On" and "Fault" pilot lights |
Operation:
 | Output frequency and speed display, can be programmed for other speed-related indications, including
RPM, CFM, FPM, and % max RPM |
 | Power loss ride-thru of 2 seconds |
 | Inertia ride-thru |
 | GPD 506 accepts either a direct-acting or a reverse acting speed command signal |
 | "Speed Search" capability, to start a rotating load |
 | DC injection braking capability, to prevent fan "wind milling" |
 | Remote Run/Stop command input |
 | An analog output of 0 to 10 VDC, proportional to output frequency, output current, or output power |
 | English language display, readout functions include: output frequency,
output voltage, output current, output power, DC bus voltage, input terminal status,
and fault status. |
 | Stall prevent (overload trip prevention) |
 | Over 100 programmable functions |
 | Either ramp-to-stop or coast-to-stop selection |
 | Auto restart: 0 to 10 attempts |
 | Volts/hertz ratio: One preset and 15 adjustable patterns |
 | Auto speed reference input signal, adjustable for bias and gain |
 | Programmable external fault input
While the GPID 506 is running, operational changes in control and display functions are possible: |
 | Accel/Decel time: 0 to 3600 seconds |
 | Frequency reference command |
 | Forward / Reverse command |
 | Monitor display |
Protective Features:
 | Current limited stall prevention during accel, decel, and run conditions |
 | Synchronized start into rotating motor via speed search |
 | DC bus CHARGE indicator (inside GPD 506) |
 | Optically-isolated operator controls |
 | Phase-to-phase / phase-to-neutral short circuit protection |
 | Electronic ground fault protection |
 | Electronic thermal motor overload protection (UL approved) |
 | Current and torque limit |
 | Current limiting DC bus fuse |
 | Fault circuit: overcurrent, over-voltage, and overtemperature |
 | Heat sink over temperature protection |
 | Input / Output phase loss protection |
Available Bypass Options:
 | Input RFI Filter |
 | Input Fusing |
 | Input Reactor |
 | DC Bus Reactor (2 to 20 HP at 208 VAC, 2 to 25 HP at 230 VAC, 1 to 25
HP at 460 VAC) |
 | Pressure Transducer, 3-15 psi |
 | Smoke Purge Logic |
 | Auto Transfer on Drive Fault |
 | Other integrally mounted options for the GPD 506 |
 | NEMA 4 or 3R enclosure (consult factory)
|
Building Automation Interface Options:
 | System 600 Apogee FLN interface LonWorks interface |
 | Metasys N2 interface |
 | RS-485 interface option; RS-232 port for Mosbus RTU standard |
 | 4-20 mA output card |
Quality Assurance:
In circuit testing of all printed circuit boards is conducted to insure proper
mounting and correct value of all components
 | Surface mount technology |
 | All printed circuit boards are burned in for 96 hours, at 85 C |
 | Final printed circuit board assemblies are functionally tested, via
computerized test equipment |
 | All fully assembled controls are tested with fully loaded induction motors |
Standards:
 | UL listed |
 | cUL listed |
 | IEC: 146A |
Y2K Compliant:
MagneTek drives have always been Year 2000 compliant and are able to correctly process dates
within and between the 20th and 21st centuries.
GPD 506 Construction:
Input Section - GPD 506 power input stage converts three phase AC line power
into a fixed DC voltage, via a solid state full wave diode rectifier, with MOV (Metal
Oxide Varistor) protection. This design eliminates power line notching.
Intermediate Section - The DC bus maintains a fixed DC voltage, with filtering and short circuit
protection and acts as a DC supply to the GPD 506 output section. It is interfaced with the
GPD 506 diagnostic logic circuit, to continuously monitor and
protect the power components. A DC bus reactor is standard above 25 HP (optional below).
Output Section - Insulated Gate Bipolar Transistors (IGBT's) convert DC bus voltage to a
variable frequency and voltage, utilizing a PWM sine-coded output to the motor. IGBT output,
allowing motor noise, at 60 Hz, to measure less than 2 dB (@1 meter) above that resulting from
across the line operation.
Non-Volatile memory (NV RAM); all programming memory is saved when the GPD
506 is disconnected from power.
Three current transformers, to detect the output current, for motor control and
protective functions.
Digital operator keypad & display, provides local control, and readout functions:
 | Run/Stop commands |
 | Speed Reference command |
 | Reset command |
 | English Language |
 | 2-Line 16 Character |