GPD 506 Special Purpose AC Drive 3/4 - 500 HP
|
Performance Features:
 | Ratings: 3/4 to 100 H P at 208 VAC,
3/4 to 125 HP at 230 VAC,
3/4 to 500 HP at 460 VAC |
 | Overload capacity:
VT 120% for 60 sec (180% peak)
CT 150% for 60 sec (200% peak) |
 | Starting torque: 150% |
 | DC injection braking: ramp or coast to stop, adjustable, current limited |
 | Electronic reversing |
 | Adjustable accel/decel: 0.1 to 3600 sec (2 each) |
 | Controlled speed range: 40:1 |
 | Critical frequency rejection-2 selectable, adjustable bands |
 | Torque limiting circuit: 30 to 180% |
 | Drive efficiency: 96 to 98% |
 | Energy $aving control: improves motor efficiency |
 | Displacement power factor: 0.98 |
 | Output frequency: 0.1 to 400 Hz |
 | Frequency resolution: 0.01 Hz with digital reference, 0.06 Hz with
analog reference |
 | Frequency regulation: 0.01 % digital (-10 to 40 C), 0.1% analog
(15 to 35 C) |
 | Torque boost: full range, auto |
 | Jog forward and reverse |
 | Power loss ride-thru: 2 sec |
 | Inertia ride-thru |
 | Selectable auto restart after momentary power loss |
 | Programmable auto restart (0 to 10 attempts) after resettable fault |
 | DC bus reactor: 30 to 125 H P at 230 VAC, 30 to 250 HP at 460 VAC |
 | Slip Compensation
|
Design Features:
 | 32-bit microprocessor logic |
 | Surface mount devices |
 | Carrier frequency: selectable to 15 kHz |
 | Keypad operator controls |
 | LCD display: English alpha/numeric sixteen character two lines 24 VDC
control logic |
 | Programmable contacts, one form C and one NO |
 | Timer function: contact-initiated |
 | RS-232 communications port |
 | Volts/hertz ratio: Programmable custom V/Hz patterns |
 | Multi-speed settings: 5 available |
 | Remote speed reference: 0 to 10 VDC or 4 to 20 mA |
 | Setpoint (PID) control with inverse input and Sleep function |
 | Signal follower: bias and gain |
 | Analog monitor output: 0 to 10 VDC |
 | NEMA 1 enclosed or protected chassis |
 | UL, cUL and cE listed; IEC 146; |
 | MTBF-. exceeds 28 years |
Protective Features:
 | Current limited stall prevention |
 | Synchronized start into rotating motor via speed search |
 | DC bus CHARGE indicator |
 | Optically-Isolated controls |
 | Phase-to-phase / phase-to-neutral short circuit protection |
 | Ground fault protection |
 | Electronic motor overload |
 | Current and torque limit |
 | Fault circuit: overcurrent, overvoltage, and overtemperature |
 | Over torque protection |
 | Under torque protection |
Service Conditions:
 | Ambient service temperature:-10 C to 40 C (104 F) NEMA 1, to 45 C (113 F) protected chassis |
 | Humidity: non-condensing to 95% |
 | Altitude: to 3300 ft; higher by derating |
 | Input voltage: +10%/-15%, 200 to 230 VAC, 380 to 460 VAC |
 | Input frequency: 50/60 Hz +/- 5% |
 | 3-phase, 3-wire, phase sequence insensitive
|
Drive with Bypass
 | Ratings:2 to 125 HP at 230 VAC,
1 to 500 HP at 460 VAC, |
 | NEMA 1 or NEMA 12 enclosure |
 | Door-interlocked circuit breaker |
 | Contactors: line, load, bypass |
 | Thermal overload relay (class 20) |
 | Control transformer |
 | Selector switches: Auto / Manual, Drive / Off / Bypass, Test / Normal |
 | Lights: Power, Fault |
 | Terminal Strip: customer use |
 | Optional auto transfer and smoke purge |
Options:
 | Remote operator station |
 | Pressure to electrical transducer |
 | Current monitor output card |
 | Input circuit breaker/disconnect |
 | Many control interface devices |
 | NEMA 4 and 12 enclosures |
 | Twelve-pulse rectification with input transformer: 30 to 125 HP at 230 VAC, 30 to 250 HP at 460 VAC |
 | Communications card: RS-232C to RS-485, MetaSys, Apogee, Echelon LonWorks and
ModBus RTU |
 | Other integrally mounted options
|
Top of Page |