Member of:

 

 

Official website of:

Federal Pump Corp.

                                                                                          Motors, Pumps, Controls, Drives, Hoists
HOME Up one level Feedback Request Quote SEARCH
GPD 305

 

 General purpose
 AC drive 1/8-5 HP

        Performance Features
bullet

Ratings: 1/8 to 5 HP at 230 VAC, 
            1/4 to 5 HP at 460 VAC

bullet

Constant torque overload rating:
150% for 1 min. (200% peak)

bullet

DC Injection braking, ramp to stop

bullet

Electronic reversing

bullet

Adjustable accel/decel:
             0.1 to 999 seconds

bullet

Controlled speed range:  40:1

bullet

Speed Regulation
             +/- 0.5 to 1% with slip compensation

bullet

Drive efficiency: 95%

bullet

Displacement power factor:  0.98

bullet

Output frequency: 1.5 to 400 Hz

bullet

Frequency resolution:
           0.01 Hz with digital reference
           0.06 / 60 Hz with analog reference

bullet

Frequency accuracy:
           0.01% with digital command
           0.5% with analog command 

bullet

Volts / hertz ratio: infinitely adjustable pattern

bullet

DC Injection braking: adjustable amplitude, duration, current limited

bullet

Torque boost: full range, auto

bullet

Power loss ride-thru: 0.5 sec.

bullet

Speed search

bullet

Auto restart

bullet

2 Critical frequency rejection settings

bullet

Slip Compensation


Design Features

bullet

16-bit microprocessor logic

bullet

Digital keypad operator with analog speed pot

bullet

LED status display

bullet

Copy Keypad Function

bullet

Remote Mount Keypad Capability

bullet

4 multifunction digital Inputs

bullet

Programmable form C output contact for customer use: 1A at 250 VAC or 30 VDC 

bullet

24 VDC control logic compatible with sourcing or sinking outputs (PNP or NPN)

bullet

Carrier frequency: 10 kHz maximum 

bullet

8 multi-speed settings plus jog speed

bullet

Remote speed reference: 0-10 VDC (20 kohms) or 4-20 mA (250 ohms) 

bullet

Signal follower: bias and gain

bullet

Analog monitor output: 0-10 VDC proportional to output frequency or output current

bullet

79 parameters

bullet

Cooling fan controlled by drive run/stop

bullet

UL and cUL listed; CE approved 

bullet

UL recognized electronic overload

bullet

MTBF: exceeds 28 years

Protective Features

bullet

Current limit, stall prevention during accel, decel, and run

bullet

Motor and drive overload

bullet

Over voltage

bullet

Instantaneous over current

bullet

Short circuit

bullet

Under voltage

bullet

Heatsink overheat

bullet

Ground fault protection

bullet

Over torque

Service Conditions

bullet

Ambient service temperature:
          -10° to 50°C (14° to 122°F)

bullet

Ambient storage temperature:
          -20° to 60°C (-4° to 140°F)

bullet

Humidity: to 95% non-condensing

bullet

Altitude: to 3280 ft; higher by derating

bullet

Service factor: 1.0

bullet

Input voltage: -15% to +10%
           200 to 230 VAC,
           380 to 460 VAC

bullet

Input frequency: +/-5%; 50/60 Hz

bullet

Phase sequence insensitive

Options

bullet

Dynamic Braking resistor (external)

bullet

Input circuit breaker / disconnect

bullet

Remote operator station

bullet

Serial Communications

bullet

NEMA 1, 12, or 4 enclosures

bullet

External DC link reactor

bullet

RS485/RS422 serial communication port (up to 32 nodes). Baud rate of 19.2 kbps

Top of Page