Ratings: 1/8 to 5 HP at 230 VAC,
1/4 to 5 HP at 460 VAC |
 | Constant torque overload rating:
150% for 1 min. (200% peak) |
 |
DC Injection braking, ramp to stop |
 |
Electronic reversing |
 |
Adjustable accel/decel:
0.1 to 999 seconds |
 |
Controlled speed range: 40:1 |
 | Speed Regulation
+/- 0.5 to 1% with slip compensation |
 |
Drive efficiency: 95% |
 |
Displacement power factor: 0.98 |
 |
Output frequency: 1.5 to 400 Hz |
 |
Frequency resolution:
0.01 Hz with digital reference
0.06 / 60 Hz with analog reference |
 |
Frequency accuracy:
0.01% with digital command
0.5% with
analog command |
 |
Volts / hertz ratio: infinitely adjustable pattern |
 |
DC Injection braking: adjustable amplitude,
duration, current limited |
 |
Torque boost: full range, auto |
 |
Power loss ride-thru: 0.5 sec. |
 |
Speed search |
 |
Auto restart |
 |
2 Critical frequency rejection settings |
 |
Slip Compensation
Design Features |
 |
16-bit microprocessor logic |
 |
Digital keypad operator with analog speed pot |
 |
LED status display |
 |
Copy Keypad Function |
 |
Remote Mount Keypad Capability |
 |
4 multifunction digital Inputs |
 |
Programmable form C output contact for customer use: 1A at 250 VAC or 30 VDC |
 |
24 VDC control logic compatible with sourcing or sinking outputs (PNP or
NPN) |
 |
Carrier frequency: 10 kHz maximum |
 |
8 multi-speed settings plus jog speed |
 |
Remote speed reference: 0-10 VDC (20 kohms) or 4-20 mA (250 ohms) |
 |
Signal follower: bias and gain |
 |
Analog monitor output: 0-10 VDC proportional to output frequency or output current |
 |
79 parameters |
 |
Cooling fan controlled by drive run/stop |
 |
UL and cUL listed; CE approved |
 |
UL recognized electronic overload |
 |
MTBF: exceeds 28 years
Protective Features |
 |
Current limit, stall prevention during
accel, decel, and run |
 |
Motor and drive overload |
 |
Over voltage |
 |
Instantaneous over current |
 |
Short circuit |
 |
Under voltage |
 |
Heatsink overheat |
 |
Ground fault protection |
 |
Over torque
Service Conditions |
 |
Ambient service temperature:
-10° to 50°C (14° to
122°F) |
 |
Ambient storage temperature:
-20° to 60°C (-4° to
140°F) |
 |
Humidity: to 95% non-condensing |
 | Altitude: to 3280 ft; higher by derating |
 |
Service factor: 1.0 |
 |
Input voltage: -15% to +10%
200 to 230 VAC,
380 to 460 VAC |
 |
Input frequency: +/-5%; 50/60 Hz |
 |
Phase sequence insensitive
Options |
 |
Dynamic Braking resistor (external) |
 |
Input circuit breaker / disconnect |
 |
Remote operator station |
 |
Serial Communications |
 |
NEMA 1, 12, or 4 enclosures |
 |
External DC link reactor |
 |
RS485/RS422 serial communication port
(up to 32 nodes). Baud rate of 19.2 kbps
|