Member of:

 

 

Official website of:

Federal Pump Corp.

                                                                                          Motors, Pumps, Controls, Drives, Hoists
HOME Up one level Feedback Request Quote SEARCH
GPD 205

General Purpose AC Drive 1/4-5 Hp

Performance Features:

bullet Ratings: 1/8 to 1 HP at 115 VAC input, 230 VAC, 3 Ph output
             1/8 to 2 HP at 230 VAC
             1/2 to 3 HP at 460 VAC
bullet Constant torque overload rating: 150% for 1 min. (200% peak)
bulletDC injection braking, ramp to stop
bullet Electronic reversing
bullet Adjustable accel/decel: 0.1 to 999 sec
bullet Controlled speed range: 40 :1
bullet Drive efficiency: 95%
bullet Displacement power factor: 0.98
bullet Output frequency: 0.1 to 400 Hz
bullet Frequency resolution: 0.1 Hz with digital reference 0.06 /60 Hz with analog reference
bullet Frequency accuracy (-100 to 50'C): 0.01% with digital command 0.1 % with analog command
bulletVolts / hertz ratio: infinitely adjustable pattern 
bulletDC injection braking: adjustable amplitude, duration, and current limit
bulletTorque boost: full range, auto
bullet Power loss ride-thru: 1 sec. min
bullet Speed search
bulletAuto restart
bullet3 Critical frequency rejection settings
bullet Slip Compensation

 

Design Features:

bullet 16-bit microprocessor logic
bullet Digital keypad operator
bullet Programmable form C contact for customer use: 1A at 250VAC or 30 VDC
bullet 24 VDC control logic
bullet Carrier frequency: 2.5-10 kHz
bullet 8 Multi-speed settings
bullet Remote speed reference: 0-10 VDC (20K ohms) or 4-20 mA (250 ohms)
bullet Signal follower: bias and gain 
bulletAnalog monitor output: 0-10 VDC proportional to output frequency or current
bullet Over 70 programmable functions 
bulletFully EMC compliant when optional RFI filter connected
bulletMTBF: exceeds 28 years

 

Protective Features:

bullet Current limited stall prevention during accel, decel and run
bulletDC bus CHARGE indicator
bulletIsolated operator controls
bulletPhase-to-phase / phase-to-neutral short circuit protection
bullet Ground fault protection
bullet UL 508C programmable electronic motor overload

 

Service Conditions:

bulletAmbient service temperature: -10 C to 50 C (14 to 122 F)
bulletAmbient storage temperature:-20 C to 60 C (-4  to 140 F)
bulletHumidity: to 90% non-condensing
bulletAltitude: to 3300 ft; higher by derating 
bulletService factor: 1.0
bulletInput voltage: single phase 115 V or three phase 200 to 230, 380 to 460, +/-10%
bulletInput frequency: 50/60 Hz, +/- 5%
bulletPhase sequence insensitive

 

Standards:

bulletUL listed
bulletcUL
bulletIEEE STD 444 (ANSI-C343)
bulletIEC: 146A


Options:

bulletDynamic braking resistor (external)
bulletDin Rail Kit
bulletAuxiliary potentiometer card
bulletRemote keypad 
bulletIRS 232/482/485 Modbus RTU serial communications
Top of Page