Submersible Sewage Pumps with Fed-Flushing
Bulletin 236

PUMP FEATURES
Type VSSF pumps have cast iron casings with smooth waterway to insure maximum
efficiency. Rabbeted construction insures complete alignment of the rotating
element. The cast iron impeller is of non-clog design and is balanced prior to
assembly.
MOTOR FEATURES
Motors are available for 1750 and 1150 R.P.M. operation with both single phase
and three phase windings. Single phase motors are furnished with a separate
capacitor box. All motors have prelubricated ball bearings, are U.L. listed for
Class 1, Group D explosion-proof service.
They are rated for intermittent duty in air at full load, continuous duty in
air at reduced load, and, if furnished with modified frames, for continuous duty
in air at full load. Shaft and fasteners are stainless steel. End brackets and
frame are cast iron. All leads are epoxy sealed.
Double seals provide protection for the electrical parts. If the outer seal
fails, the inner seal protects the motor while water enters the oilfilled
chamber. A moisture sensing probe detects the entry of water into the chamber
and sends a signal to the appropriate alarm.
Motors are furnished with 25-feet of power and control cable and grounding
wire. The standard motors are rated for operation in 40°C (104°F) water, but
can be modified for higher ambient temperatures. Thermal protection is a
standard feature.
FED-FLUSH FITTINGS
VSSF and VSSF-QD units are designed so that sewage entering the pit shall flow
through stainless steel strainer baskets in the pump discharge pipes. Solids are
retained in the baskets and the liquid continues through the pump casings into
the pit. This prevents possible clogging of the pump casing and impeller by the
solids.
The solids are flushed into the discharge line during the pump discharge
cycle and a control valve prevents backup into the house line. An overflow
fitting allows liquid to flow directly into the pit during discharge cycles, if
necessary.
QUICK-DISCONNECT FITTINGS (OPTIONAL)
VSSF pumps can be furnished with Quick-Disconnect fittings (VSSF-QD) if desired.
These fittings permit lifting of the pumps from the pit for inspection or
service, without anyone entering the sewage pit and without disturbing the pump
discharge pipes and electrical connections.
The pump is lowered into the pit, held in position by its guide rail and
automatically completes the discharge connection. The angled discharge mating
flange is designed to assure a complete discharge seal.
MODIFICATIONS AND ACCESSORIES
Pumps can be furnished with bronze impellers, stainless steel fasteners, longer
cables and special seals. Accessory items include moisture-detection relays,
motor controls, high water alarms, steel covers and grouting frames or hinged
access doors for concrete pits, and steel, cast iron or fiberglass receiving
basins.
CONTROLS
The recommended control arrangement for VSSF and VSSF-QD pumps is the Submers-a-bulb
control (see SBS Bulletin 263) which includes on-off mercury bulbs, high water
alarm, temperature sensor cut-out, moisture sensor alarm and automatic
alternator for duplex units.
Float controls are also available.
Click Here for List Prices
Selection Table
|
1750 RPM
|
UNIT
NUMBERS
WITH
FED-FLUSH
FITTINGS |
UNIT
NUMBERS
WITH
FED-FLUSH
FITTINGS
&
QUICK-DISCONNECT
FITTINGS |
GPM |
DISCH
HEAD
(FEET) |
MOTOR
HP. |
DISCH
SIZE
(INCHES) |
|
VSSF-4A-1-4
VSSF-4A-1½-4
VSSF-4A-2-4
VSSF-4A-3-4
VSSF-4A-5-4 |
VSSF-QD-4A-1-4
VSSF-QD-4A-1½-4
VSSF-QD-4A-2-4
VSSF-QD-4A-3-4
VSSF-QD-4A-5-4 |
50 |
26
33
42
48
58 |
1
1½
2
3
5 |
4
4
4
4
4 |
|
VSSF-4A-1-4
VSSF-4A-1½-4
VSSF-4A-2-4
VSSF-4A-3-4
VSSF-4A-5-4 |
VSSF-QD-4A-1-4
VSSF-QD-4A-1½-4
VSSF-QD-4A-2-4
VSSF-QD-4A-3-4
VSSF-QD-4A-5-4 |
75 |
25
32
40
45
56 |
1
1½
2
3
5 |
4
4
4
4
4 |
|
VSSF-4A-1-4
VSSF-4A-1½-4
VSSF-4A-2-4
VSSF-4A-3-4
VSSF-4A-5-4 |
VSSF-QD-4A-1-4
VSSF-QD-4A-1½-4
VSSF-QD-4A-2-4
VSSF-QD-4A-3-4
VSSF-QD-4A-5-4 |
100 |
21
30
35
42
55 |
1
1½
2
3
5 |
4
4
4
4
4 |
|
VSSF-4A-1-4
VSSF-4A-1½-4
VSSF-4A-2-4
VSSF-4A-3-4
VSSF-4A-5-4 |
VSSF-QD-4A-1-4
VSSF-QD-4A-1½-4
VSSF-QD-4A-2-4
VSSF-QD-4A-3-4
VSSF-QD-4A-5-4 |
125 |
19
26
33
38
53 |
1
1½
2
3
5 |
4
4
4
4
4 |
|
VSSF-4A-1-4
VSSF-4A-1½-4
VSSF-4A-2-4
VSSF-4A-3-4
VSSF-4A-5-4
VSSF-4C-7½-4 |
VSSF-QD-4A-1-4
VSSF-QD-4A-1½-4
VSSF-QD-4A-2-4
VSSF-QD-4A-3-4
VSSF-QD-4A-5-4
VSSF-QD-4C-7½-4 |
150 |
16
23
29
36
52
62 |
1
1½
2
3
5
7½ |
4
4
4
4
4
4 |
|
VSSF-4A-1-4
VSSF-4A-1½-4
VSSF-4A-2-4
VSSF-4A-3-4
VSSF-4A-5-4
VSSF-4C-7½-4 |
VSSF-QD-4A-1-4
VSSF-QD-4A-1½-4
VSSF-QD-4A-2-4
VSSF-QD-4A-3-4
VSSF-QD-4A-5-4
VSSF-QD-4C-7½-4 |
200 |
7
15
25
32
47
60 |
1
1½
2
3
5
7½ |
4
4
4
4
4
4 |
|
VSSF-4A-1½-4
VSSF-4A-2-4
VSSF-4A-3-4
VSSF-4A-5-4
VSSF-4A-7½-4
VSSF-4C-10-4
VSSF-4C-15-4 |
VSSF-QD-4A-1½-4
VSSF-QD-4A-2-4
VSSF-QD-4A-3-4
VSSF-QD-4A-5-4
VSSF-QD-4A-7½-4
VSSF-QD-4C-10-4
VSSF-QD-4C-15-4 |
250 |
8
16
25
42
50
70
86 |
1½
2
3
5
7½
10
15 |
4
4
4
4
4
4
4 |
|
VSSF-4A-2-4
VSSF-4A-3-4
VSSF-4A-5-4
VSSF-4A-7½-4
VSSF-4C-10-4
VSSF-4C-15-4 |
VSSF-QD-4A-2-4
VSSF-QD-4A-3-4
VSSF-QD-4A-5
-4
VSSF-QD-4A-7½-4
VSSF-QD-4C-10-4
VSSF-QD-4C-15-4 |
300 |
9
20
35
49
68
83 |
2
3
5
7½
10
15 |
4
4
4
4
4
4 |
|
VSSF-4A-3-4
VSSF-4A-5-4
VSSF-4C-7½-4
VSSF-4C-10-4
VSSF-4C-15-4 |
VSSF-QD-4A-3-4
VSSF-QD-4A-5-4
VSSF-QD-4C-7½-4
VSSF-QD-4C-10-4
VSSF-QD-4C-15-4 |
350 |
16
30
48
65
80 |
3
5
7½
10
15 |
4
4
4
4
4 |
|
VSSF-4C-3-4
VSSF-4C-5-4
VSSF-4C-7½-4
VSSF-4C-10-4
VSSF-4C-15-4
VSSF-4C-20-4 |
VSSF-QD-4C-3-4
VSSF-QD-4C-5-4
VSSF-QD-4C-7½-4
VSSF-QD-4C-10-4
VSSF-OD-4C-15-4
VSSF-QD-4C-20-4 |
400 |
15
29
45
61
75
82 |
3
5
7½
10
15
20 |
4
4
4
4
4
4 |
|
VSSF-4C-5-4
VSSF-4C-7½-4
VSSF-4C-10-4
VSSF-4C-15-4
VSSF-4C-20-4
VSSF-4E-25-4
VSSF-4E-30-4
VSSF-4E-40-4 |
VSSF-QD-4C-5-4
VSSF-QD-4C-7½-4
VSSF-QD-4C-10-4
VSSF-QD-4C-15-4
VSSF-QD-4C-20-4
VSSF-QD-4E-25-4
VSSF-QD-4E-30-4
VSSF-QD-4E-40-4 |
500 |
23
38
55
70
77
88
102
120 |
5
7½
10
15
20
25
30
40 |
4
4
4
4
4
4
4
4 |
|
VSSF-4C-5-4
VSSF-4C-7½-4
VSSF-4C-10-4
VSSF-4C-15-4
VSSF-4C-20-4
VSSF-4E-25-4
VSSF-4E-30-4
VSSF-4E-40-4 |
VSSF-QD-4C-5-4
VSSF-QD-4C-7½-4
VSSF-QD-4C-10-4
VSSF-QD-4C-15-4
VSSF-QD-4C-20-4
VSSF-QD-4E-25-4
VSSF-QD-4E-30-4
VSSF-QD-4E-40-4 |
600 |
17
30
50
64
72
82
100
115 |
5
7½
10
15
20
25
30
40 |
4
4
4
4
4
4
4
4 |
|
VSSF-4E-15-4
VSSF-4E-20-4
VSSF-4E-25-4
VSSF-4E-30-4
VSSF-4E-40-4 |
VSSF-QD-4E-15-4
VSSF-QD-4E-20-4
VSSF-QD-4E-25-4
VSSF-QD-4E-30-4
VSSF-QD-4E-40-4 |
800 |
43
60
68
88
110 |
15
20
25
30
40 |
4
4
4
4
4 |
|
1150 RPM
|
UNIT
NUMBERS
WITH
FED-FLUSH
FITTINGS |
UNIT
NUMBERS
WITH
FED-FLUSH
FITTINGS
&
QUICK-DISCONNECT
FITTINGS |
GPM |
DISCH
HEAD
(FEET) |
MOTOR
HP. |
DISCH
SIZE
(INCHES) |
|
VSSF-4A-3/4-6
VSSF-4A-1-6
VSSF-4A-1½-6
VSSF-4C-3-6
VSSF-4E-5-6
VSSF-4E-7½-6 |
VSSF-QD-4A-3/4-6
VSSF-QD-4A-1-6
VSSF-QD-4A-1½-6
VSSF-QD-4C-3-6
VSSF-QD-4E-5-6
VSSF-QD-4E-7½-6 |
50 |
23
28
31
36
48
61 |
3/4
1
1½
3
5
7½ |
4
4
4
4
4
4 |
|
VSSF-4A-3/4-6
VSSF-4A-1-6
VSSF-4A-1½-6
VSSF-4C-3-6
VSSF-4E-5-6
VSSF-4E-7½-6 |
VSSF-QD-4A-3/4-6
VSSF-QD-4A-1-6
VSSF-QD-4A-1½-6
VSSF-QD-4C-3-6
VSSF-QD-4E-5-6
VSSF-QD-4E-7½-6 |
75 |
19
23
29
35
46
59 |
3/4
1
1½
3
5
7½ |
4
4
4
4
4
4 |
|
VSSF-4A-3/4-6
VSSF-4A-1-6
VSSF-4A-1½-6
VSSF-4C-3-6
VSSF-4E-5-6
VSSF-4E-7½-6 |
VSSF-QD-4A-3/4-6
VSSF-QD-4A-1-6
VSSF-QD-4A-1½-6
VSSF-QD-4C-3-6
VSSF-QD-4E-5-6
VSSF-QD-4E-7½-6 |
100 |
15
20
27
33
44
58 |
3/4
1
1½
3
5
7½ |
4
4
4
4
4
4 |
|
VSSF-4A-1-6
VSSF-4A-1½-6
VSSF-4C-3-6
VSSF-4E-5-6
VSSF-4E-7½-6 |
VSSF-QD-4A-1-6
VSSF-QD-4A-1½-6
VSSF-QD-4C-3-6
VSSF-QD-4E-5-6
VSSF-QD-4E-7½-6 |
125 |
18
25
31
42
57 |
1
1½
3
5
7½ |
4
4
4
4
4 |
|
VSSF-4A-1-6
VSSF-4A-1½-6
VSSF-4A-2-6
VSSF-4C-3-6
VSSF-4E-5-6
VSSF-4E-7½-6 |
VSSF-QD-4A-1-6
VSSF-QD-4A-1½-6
VSSF-QD-4A-2-6
VSSF-QD-4C-3-6
VSSF-QD-4E-5-6
VSSF-QD-4E-7½-6 |
150 |
13
21
24
30
40
56 |
1
1½
2
3
5
7½ |
4
4
4
4
4
4 |
|
VSSF-4A-1½-6
VSSF-4A-2-6
VSSF-4C-3-6
VSSF-4C-5-6
VSSF-4E-7½-6 |
VSSF-QD-4A-1½-6
VSSF-QD-4A-2-6
VSSF-QD-4C-3-6
VSSF-QD-4C-5-6
VSSF-QD-4E-7½-6 |
200 |
16
22
28
38
54 |
1½
2
3
5
7½ |
4
4
4
4
4 |
|
VSSF-4A-1½-6
VSSF-4C-2-6
VSSF-4C-3-5
VSSF-4C-5-6
VSSF-4E-7½-6
VSSF-4E-10-6 |
VSSF-QD-4A-1½-6
VSSF-QD-4C-2-6
VSSF-QD-4C-3-6
VSSF-QD-4C-5-6
VSSF-QD-4E-7½-6
VSSF-QD-4E-10-6 |
250 |
14
19
26
35
50
58 |
1½
2
3
5
7½
10 |
4
4
4
4
4
4 |
|
VSSF-4C-2-6
VSSF-4C-3-6
VSSF-4C-5-6
VSSF-4E-7½-6
VSSF-4E-10-6
VSSF-4E-15-6 |
VSSF-QD-4C-2-6
VSSF-QD-4C-3-6
VSSF-QD-4C-5-6
VSSF-QD-4E-7½-6
VSSF-QD-4E-10-6
VSSF-QD-4E-15-6 |
300 |
15
23
31
47
54
59 |
2
3
5
7½
10
15 |
4
4
4
4
4
4 |
|
VSSF-4C-2-6
VSSF-4C-3-6
VSSF-4C-5-6
VSSF-4E-7½-6
VSSF-4E-10-6
VSSF-4E-15-6 |
VSSF-QD-4C-2-6
VSSF-QD-4C-3-6
VSSF-QD-4C-5-6
VSSF-QD-4E-7½-6
VSSF-QD-4E-10-6
VSSF-QD-4E-15-6 |
350 |
13
21
28
42
50
58 |
2
3
5
7½
10
15 |
4
4
4
4
4
4 |
|
VSSF-4C-2-6
VSSF-4C-3-6
VSSF-4C-5-6
VSSF-4E-7½-6
VSSF-4E-10-6
VSSF-4E-15-6 |
VSSF-QD-4C-2-6
VSSF-QD-4C-3-6
VSSF-QD-4C-5-6
VSSF-QD-4E-7½-6
VSSF-QD-4E-10-6
VSSF-QD-4E-15-6 |
400 |
12
20
24
38
44
57 |
2
3
5
7½
10
15 |
4
4
4
4
4
4 |
|
VSSF-4C-3-6
VSSF-4C-5-6
VSSF-4E-7½-6
VSSF-4E-10-6
VSSF-4E-15-6 |
VSSF-QD-4C-3-6
VSSF-QD-4C-5-6
VSSF-QD-4E-7½-6
VSSF-QD-4E-10-6
VSSF-QD-4E-15-6 |
500 |
15
23
31
42
54 |
3
5
7½
10
15 |
4
4
4
4
4 |
|
VSSF-4E-5-6
VSSF-4E-7½-6
VSSF-4E-10-6
VSSF-4E-15-6 |
VSSF-QD-4E-5-6
VSSF-QD-4E-7½-6
VSSF-QD-4E-10-6
VSSF-QD-4E-15-6 |
600 |
16
29
40
50 |
5
7½
10
15 |
4
4
4
4 |
|
Minimum Dimensions

Suggested Specifications for Architects and
Engineers
Furnish and install, as shown on plans, a Federal Pump Corporation Type VSSF
(VSSF-QD if Quick-Disconnect fittings are required) duplex submersible Fed-Flush
sewage pump unit. The pumps shall be of cast iron construction with non-clog,
balanced impellers, and rated as shown in the pump schedule.
The unit shall be so designed that sewage entering the pit shall flow through
a stainless steel strainer basket in each pump discharge pipe. Solids will be
retained in the baskets and the liquid will continue through the pump casings
into the pit. Solids will be flushed into the discharge line during the pump
discharge cycle and a control valve ahead of each pump shall prevent backup into
the house line. An overflow fitting shall allow liquid to flow directly into the
pit during pump discharge cycles, if necessary.
Each motor shall be submersible, air filled, protected by double-sealed oil
chamber, and shall have a stainless steel shaft, thermal sensors, moisture
sensing probe in the seal chamber, and 25-ft. waterproof cable. Motors shall be
rated as shown in the pump schedule.
Pump control shall be by a Type SBS Submers-a-bulb controller, including four
mercury tube bulbs on a Style 1 suspension bracket. A NEMA-4 junction box shall
be provided together with a control panel in a NEMA-1 wall-mounting enclosure,
including therein fusible disconnect switches, magnetic starters, HOA selector
switches, automatic pump alternator, required relays and transformers, pump-run
lights plus an alarm bell and silencer with lights to indicate high water and
outer seal failure conditions.
For units to be furnished with quick-disconnect fittings (VSSF-QD), add
the following specification paragraph:
Each pump shall have Quick-Disconnect fittings including base plate, guide
brackets, base elbow and lifting cable. Each pump shall be removable from the
pit by riding up on the guide rail (4x4 wide flange beam) without disconnecting
any piping or electrical connection, and without anyone entering the pit. Pumps
shall be relowered to their operating position in the same manner.
For concrete pit and thru-cover pump discharge, add the following
specification paragraph:
Furnish a Style PF-1 angle iron pit frame and steel cover for the concrete wet
pit. The pit cover shall be gas-tight with pump removal plates, flanged openings
for pump discharge pipes, vent connection and control openings. The frame and
cover shall have a corrosion-resistant coating and shall be fabricated for a pit
size and top opening size as shown in the pump schedule.
For concrete pit and under-cover pump discharge, add the following
specification paragraph:
The pumps shall discharge through the side wall of the wet pit. Provision shall
also be made in the side wall for venting and for control and power wires.
Furnish a Federal Type Q access door for installation in the top slab of the
concrete pit. Pit size and door size shall be as shown in the pump schedule.
The access door shall be single-leaf with steel frame, diamond steel leaf,
steel hinges and torsion bars for easy opening. The door and frame shall have a
corrosion-resistant coating.
Also furnish a concrete valve chamber of the size shown in the pump schedule,
with steel-covered top access opening, to house the discharge check valves, gate
valves and wye fitting.
PUMP SCHEDULE:
Pump Model No.: __________, GPM Per Pump: __________,
TDH (Ft.): __________, Motor HP:__________, RPM: __________,
Phase: __________, 60 Cycles, Volts: __________
Pump Pit Size: __________in. x __________in. x __________in. deep.
Top Opening (or Access Door) Size: __________in. x __________in.
Valve Chamber Size (If Any): __________in. x __________in x __________in deep