Member of:

 

 

Official website of:

Federal Pump Corp.

                                                                                          Motors, Pumps, Controls, Drives, Hoists
HOME Up one level Feedback Request Quote SEARCH
Type VSABM & VSABV

VSABM Curves
VSABM Dimensions
VSABM Parts List

Dry Pit Sewage Pumps
Bulletin 230B

bullet

Non-Clog

bullet

Centrifugal Design

bullet

Minimum Floor Space

bullet

Sewage and Industrial Wastes

FEATURES

IMPELLER:
Cast iron, enclosed, non-clog design. No edges or corners to trap solids. Dynamically and hydraulically balanced. Renewable bronze wearing ring minimizes slippage, wear and seizing.

CASING:
Close-grained cast iron, streamlined with internal passages designed to effect smooth flow.

SHAFT:
Large diameter, stainless steel construction, turned, ground and polished. Impeller is secured to shaft by stainless steel key and bronze impeller nut and washer.

STUFFING BOX:
Extra deep stuffing box with generous number of packing rings. Adjustable bronze gland, with studs and nuts.

BEARINGS:
Bronze sleeve type radial bearing, and ball thrust bearing are both mounted in cast iron combination bearing housing and motor pedestal. Tongue-in-groove construction insures perfect alignment. Bearings are grease lubricated.

COUPLING:
Flexible type, precision-machined construction, held by key and set screws. Eliminates wear on metal jaws. Load transmitted by cushion compression.

BASE:
Heavy close-grained cast iron base support; has integral flanged suction ell, and easily removable large clean-out plug.

CONTROLS:
Motors should be provided with magnetic starters for thermal overload and low voltage protection. Pilot control devices for the wet well are available in any of the following types; float switches. electrodes, bubblers, diaphragm switches, and FEDERAL SUBMERS-A-BULB (See Bulletin 253).

ACCESSORIES AND MODIFICATIONS:
The following accessory items are available for use with VSABM sewage pumps: Steel or cast iron covers for wet well, small sump pumps for dry pit drainage, dehumidifiers and blowers for dry pit ventilation, high water alarms, alternators, special materials of construction for pumps, special enclosures for motors and controls. control panels, etc.

Click Here for List Prices

Click Here for Parts List & Prices

Click Here for Performance Curves

Click Here for Dimensions and Installation Diagrams

Engineering Selection Tables

1750 RPM

UNIT NO.

G.P.M.

DISCH. HEAD (FEET)

MOTOR H.P.

VSABM-4B-1-4

VSABM-4B-1½-4

VSABM-4B-2-4

VSABM-4B-3-4

VSABM-4B-5-4

VSABM-4B-7½-4

VSABM-4B-10-4

50

27

37

44

48

62

67

78

1

2

3

5

10

VSABM-4B-1-4

VSABM-4B-1½-4

VSABM-4B-2-4

VSABM-4B-3-4
VSABM-4B-5-4

VSABM-4B-7½-4

VSABM-4B-10-4

100

21

30

37

40

60

65

75

1

2

3

5

10

VSABM-4B-1-4

VSABM-4B-1½-4

VSABM-4B-2-4

VSABM-4B-3-4
VSABM-4B-5-4

VSABM-4B-7½-4

VSABM-4B-10-4

150

15

25

28

35

55

62

71

1

2

3

5

10

VSABM-4B-1-4

VSABM-4B-1½-4

VSABM-4B-2-4

VSABM-4B-3-4
VSABM-4B-5-4

VSABM-4B-7½-4

VSABM-4B-10-4

200

9

16

24

32

47

58

68

1

2

3

5

10

VSABM-4B-1½-4

VSABM-4B-2-4

VSABM-4B-3-4

VSABM-4B-5-4

VSABM-4B-7½-4

VSABM-4B-10-4

VSABM-4E-15-4

VSABM-4E-20-4

VSABM-4E-25-4

VSABM-4E-30-4

250

8

16

25

44

55

64

93

110

130

150

2

3

5

10

15

20

25

30

VSABM-4B-2-4

VSABM-4B-3-4

VSABM-4B-5-4

VSABM-4B-7½-4

VSABM-4E-10-4
VSABM-4E-15-4

VSABM-4E-20-4

VSABM-4E-25-4

VSABM-4E-30-4

300

9

20

38

51

61

90

106

125

l45

2

3

5

10
15

20

25

30

UNIT NO.

G.P.M.

DISCH. HEAD (FEET)

MOTOR H.P.

VSABM-4B-3-1

VSABM-4B-5-4

VSABM-4B-7½-4

VSABM-4B-10-4

VSABM-4E-15-4

VSABM-4E-20-4

VSABM-4E-25-4

VSABM-4E-30-4

400

16

30

43

53

85

102

115

142

3

5

10

15

20

25

30

VSABM-4B-5-4

VSABM-4B-7½-4

VSABM-4B-10-4

VSABM-4E-15-4

VSABM-4E-20-4

VSABM-4E-25-4

VSABM-4E-30-4

500

22

34

45

80

95

110

135

5

10

15

20

25

30

VSABM-4B-7½-4

VSABM-4B-10-4

VSABM-4E-15-4

VSABM-4E-20-4

VSABM-4E-25-4

VSABM-4E-30-4

600

25

37

70

90

105

130

71

10

15

20

25

30

VSABM-4E-15-4

VSABM-4E-20-4
VSABM-4E-25-4

VSABM-4E-30 4

750

55

75

90

115

15
20
25

30

VSABM-6H-20-4

VSABM-6H-25-4

VSABM-6H-30-4

VSABM-6H-40-4

VSABM-6H-50-4

1000

55

65

73

95

116

20

25

30

40

50

VSABM-6H-20-4

VSABM-6H-25-4

VSABM-6H-30-4

VSABM-6H-40-4

VSABM-6H-50-4

1250

45

55

65

90

110

20

25

30

40

50

VSABM-6H-20-4

VSABM-6H-25-4

VSABM-6H-30-4

VSABM-6H-40-4

VSABM-6H-50-4

1500

35

45

56

78

100

20

25

30

40

50

VSABM-6H-40-4

VSABM-6H-50-4

1750

67

90

40

50

 

1150 RPM

UNIT NO.

G.P.M.

DISCH. HEAD (FEET)

MOTOR H.P.

VSABM-4B-1-6

VSABM-4B-1½-6

VSABM-4B-2-6

VSABM-4B-3-6

50

18

24

28

38

1

2

3

VSABM-4B-1-6

VSABM-4B-1½-6

VSABM-4B-2-6

VSABM-4B-3-6

100

16

22

26

32

1

2

3

VSABM-4B-1-6

VSABM-4B-1½-6

VSABM-4B-2-6

VSABM-4B-3-6

150

14

19

24

28

1

2

3

VSABM-4B-1-6

VSABM-4B-1½-6

VSABM-4B-2-6

VSABM-4B-3-6

200

13

17

22

27

1

2

3

VSABM-4B-1-6

VSABM-4B-1½-6

VSABM-4B-2-6

VSABM-4B-3-6

250

10

15

18

24

1

2

3

VSABM-4B-1½-6

VSABM-4B-2-6

VSABM-4B-3-6

VSABM-4E-5-6

VSABM-4E-7½-6

VSABM-4E-10-6

300

12

15

22

37

50

62

2

3

5

10

UNIT NO.

G.P.M.

DISCH. HEAD (FEET)

MOTOR H.P.

VSABM-4B-3-6

VSABM-4E-5-6

VSABM-4E-7½-6

VSABM-4E-10-6

400

17

32

45

58

3

5

10

VSABM-4E-3-6

VSABM-4E-5-6

VSABM-4E-7½-6

VSABM-4E-10-6

500

15

25

40

55

3

5

10

VSABM-4E-5-6

VSABM-4E-7½-6

VSABM-4E-10-6

VSABM-6H-15-6

600

18

30

47

53

5

10

15

VSABM-6H-3-6

VSABM-6H-5-6

VSABM-6H-7½-6

VSABM-6H-10-6

VSABM-6H-15-6

750

13

20

32

40

50

3

5

10

15

VSABM-6H-5-6

VSABM-6H-7½-6

VSABM-6H-10-6

VSABM-6H-15-6

1000

15

25

35

47

5

10

15

VSABM-6H-7½-6

VSABM-6H-10-6

VSABM-6H-15-6

1250

18

28

40

10

15

VSABM-6H-10-6

VSABM-6H-15-6

1500

22

35

10

15

 

 

850 RPM

UNIT NO.

G.P.M.

DISCH. HEAD (FEET)

MOTOR H.P.

VSABM-4B-1/2-8

VSABM-4B-3/4-8

VSABM-4B-1-8

VSABM-4B-1½-8

50

11

14

16

19

1/2

3/4

1

VSABM-4B-1/2-8

VSABM-4B-3/4-8

VSABM-4B-1-8

VSABM-4B-1½-8

100

8

12

14

16

1/2

3/4

1

VSABM-4B-1/2-8

VSABM-4B-3/4-8

VSABM-4B-1-8

VSABM-4B-1½-8

150

6

10

12

14

1/2

3/4

1

VSABM-4B-1/2-8

VSABM-4B-3/4-8

VSABM-4B-1-8

VSABM-4B-1½-8

200

5

8

11

13

1/2

3/4

1

VSABM-4B-3/4-8

VSABM-4B-1-8

VSABM-4B-1½-8

VSABM-4E-2-8

VSABM-4E-3-8

VSABM-4E-5-8

250

6

9

12

15

23

35

3/4

1

2

3

5

UNIT NO.

G.P.M.

DISCH. HEAD (FEET)

MOTOR H.P.

VSABM-4B-1-8

VSABM-4B-1½-8

VSABM-4E-2-8

VSABM-4E-3-8

VSABM-4E-5-8

300

7

10

13

22

33

1

2

3

5

VSABM-4E-2-8

VSABM-4E-3-8

VSABM-4E-5-8

400

9

18

30

2

3

5

VSABM-4E-3-8

VSABM-4E-5-8

500

13

26

3

5

VSABM-6H-3-8

VSABM-6H-5-8

VSABM-6H-7½-8

750

12

22

27

3

5

VSABM-6H-5-8

VSABM-6H-7½-8

1000

17

22

5

 

 

 

EXPLANATION OF UNIT NUMBERS:
Example: VSABM-4B-5-4; VSA indicates non-clog sewage pump, BM indicates base-mounted dry pit type, -4B indicates discharge size and volute size, -5 indicates the motor horsepower, and -4 indicates the motor speed (-4=4-pole 1750 RPM, -6=6-pole 1150 RPM, -8 = 8-pole 870 RPM).

Suggested Specifications for Architects and Engineers

Furnish and install as shown on plans a Federal Pump Corporation Type VSABM standard-fitted, vertical, non-clog dry pit simplex (or duplex) sewage pump unit, (each) pump rated at _____G.P.M. at a Total Dynamic Head of _____ft. and directly driven thru a flexible coupling by _____H.P, _____R.P.M, _____phase, _____cycles, _____volts, drip-proof (or totally-enclosed, explosion-proof motor(s).

Pump(s) shall have cast iron enclosed non-clog impeller, cast iron casing, stainless steel shaft secured to impeller by key and nut. Deep stuffing box shall have adjustable bronze gland. Radial bearing shall be bronze sleeve type and thrust bearing shall be ball type, both mounted in cast iron combination bearing housing and motor pedestal of tongue-in-groove construction. Coupling to be flexible type and base to be heavy cast iron with clean-out plug.

Furnish a magnetic line voltage type starter in NEMA-1 (or NEMA-4 watertight; NEMA-7 explosion-proof) wall-mounting enclosure for (each) motor, to provide thermal overload and low voltage protection, plus control circuit.

Note: Specify level control for installation in wet well. Level controls can be any of the following: float switch, electrode, diaphragm switch, bubbler or FEDERAL SUBMERS-A-BULB (See Bulletin 253).