GENERAL MOTOR INFORMATION:
ELECTRIC MOTORS FALL INTO TWO MAJOR CATEGORIES, A.C. AND D.C.. SINCE D.C. MOTORS ARE FURNISHED BY FEDERAL ONLY ON SPECIAL ORDER, WE WILL LIMIT THE FOLLOWING DATA TO A.C. MOTORS.

A.C. MOTORS FALL INTO TWO CATEGORIES, SINGLE-PHASE AND THREE-PHASE. SINGLE-PHASE MOTORS ARE BUILT WITH ONE CONTINUOUS STATOR WINDING AND, THEREFORE, THE MAGNETIC FIELD CREATED DOES NOT REVOLVE AS IT DOES IN A THREE-PHASE MOTOR. FOR THIS REASON, SINGLE-PHASE MOTORS REQUIRE AN AUXILIARY METHOD OF STARTING. SINGLE-PHASE MOTORS OFFERED BY FEDERAL ARE OF THE CAPACITOR-START TYPE WHICH INDICATES THAT A CAPACITOR IS USED IN SERIES WITH A SEPARATE STARTING WINDING (THE CAPACITOR IMPROVES THE STARTING TORQUE); WHEN A SUFFICIENT SPEED IS REACHED THE CAPACITOR AND STARTING WINDING ARE CUT OUT BY A CENTRIFUGAL SWITCH.

THREE-PHASE CURRENT CONSISTS OF THREE ALTERNATING CURRENTS OF EQUAL FREQUENCY AND AMPLITUDE, BUT BEING PHASED EXACTLY 1/3RD OF A PERIOD APART. THREE-PHASE CURRENT REQUIRES THREE WIRES, WHILE SINGLE-PHASE CURRENT REQUIRES TWO. HOWEVER, THREE TIMES AS MUCH POWER IS DISTRIBUTED OVER THE THREE-PHASE LINES THAN OVER THE SINGLE-PHASE LINES, MAKING THREE-PHASE CURRENT MORE ECONOMICAL ABOVE THE 1/2 HP LEVEL. THE PHASING OF THREE-PHASE CURRENT ESTABLISHES A ROTATING MAGNETIC FIELD IN THE MOTOR STATOR, WHICH INDUCES A MAGNETIC FIELD IN THE ROTOR, THUS DRAGGING THE ROTOR AROUND. 

THREE-PHASE MOTORS OFFERED BY FEDERAL (ON STANDARD EQUIPMENT) ARE OF THE SQUIRREL-CAGE TYPE, WHICH MEANS THAT THE ROTOR CONSTRUCTION RESEMBLES A SQUIRREL CAGE, BEING COMPOSED OF PARALLEL AXIAL BARS. THE SPEED OF A SQUIRREL-CAGE MOTOR DEPENDS ON THE FREQUENCY OF CURRENT SUPPLIED AND THE NUMBER OF POLES WIRED INTO THE MOTOR. TWO-POLE MOTORS (3600 RPM) ARE THE FASTEST (4-POLE - 1800 RPM; 6-POLE - 1200 RPM; 8-POLE - 900 RPM). THE ACTUAL RUNNING SPEEDS ARE SOMEWHAT LESS THAN THE SYNCHRONOUS SPEEDS STATED ABOVE; THIS DIFFERENCE IS CALLED SLIP. SLIP OCCURS BECAUSE THE ROTATING MAGNETIC FIELD OF THE STATOR MUST CONSTANTLY OVERTAKEN AND BE CUT BY THE ROTOR WINDINGS. 

SQUIRREL-CAGE MOTOR DEFINITIONS:
EFFICIENCY
- RATIO OF POWER OUT TO POWER IN, EXPRESSED AS A PERCENTAGE.
POWER
FACTOR - RATIO OF REAL POWER TO APPARENT POWER, EXPRESSED A PERCENTAGE.
ROTATION
- DIRECTION OF ROTATION OF THE ROTOR AND SHAFT (MAY BE REVERSED BY INTERCHANGING ANY TWO MOTOR LEADS).
TORQUE
- TURNING EFFECT OF A MOTOR, EXPRESSED IN FOOT-POUNDS.
HORSEPOWER
- RATE OF DOING WORK ( 1 HP EQUALS 33,000 FOOT-POUNDS PER MINUTE). 
FULL LOAD TORQUE
- THE STEADY CONSTANT TORQUE AT RATED LOAD.

STARTING TORQUE
- ADDITIONAL TORQUE REQUIRED TO START THE LOAD ( ABOUT 210% OF FULL LOAD TORQUE). 
BREAKDOWN TORQUE
- ADDITIONAL TORQUE CAPACITY TO PREVENT STALLING FROM OVERLOADS ( ABOUT 270% OF FULL LOAD TORQUE).

SERVICE FACTOR - MULTIPLIER WHICH APPLIED TO HP RATING INDICATES PERMISSIBLE OVERLOADING (VARIES FROM APPROX. 1.25 FOR I HP MOTORS TO 1.15 FOR 3 HP MOTORS AND LARGER.
NEMA DESIGN DESIGNATION
- STD. FEDERAL SQUIRREL-CAGE MOTORS ARE NEMA DESIGN B, INDICATING NORMAL STARTING TORQUE, HIGH OVERLOAD TORQUE AND LOWER STARTING CURRENT, FOR GENERAL PURPOSE APPLICATIONS.

INSULATION CLASS:
CURRENT NEMA FRAME MOTORS ARE FURNISHED WITH CLASS B INSULATION FOR TEMPERATURE RISE RATINGS OF APPROXIMATELY 70ºC.

STANDARD OPERATING CONDITIONS:
STANDARD SQUIRREL CAGE INDUCTION MOTORS ARE DESIGNED TO OPERATE SUCCESSFULLY UNDER THE FOLLOWING CONDITIONS:
1. AMBIENT (ROOM) TEMPERATURE NOT EXCEEDING 40ºC (104ºF).
2. A VARIATION IN VOLTAGE OF NOT MORE THAN 10% PLUS OR MINUS THE NAMEPLATE RATING. 
3. A VARIATION IN FREQUENCY (CYCLES OR HERTZ) OF NOT MORE THAN 5% ABOVE OR BELOW THE NAMEPLATE RATING.
4. AN ALTITUDE NOT EXCEEDING 3300 FEET.
5. ATMOSPHERIC CONDITIONS (DUST, MOISTURE, FUMES) WHICH WILL NOT SERIOUSLY INTERFERE WITH VENTILATION.

MOTOR ENCLOSURES:
1. DRIP-PROOF - AN OPEN MOTOR SO CONSTRUCTED THAT DROPS FALLING AT ANY ANGLE NOT GREATER THAN 15º FROM THE VERTICAL CANNOT ENTER.
2. TOTALLY ENCLOSED - PREVENTS FREE EXCHANGE OF AIR BETWEEN INSIDE AND OUTSIDE OF MOTOR (NOT AIRTIGHT).
3. TOTALLY ENCLOSED FAN-COOLED - TOTALLY ENCLOSED WITH A FAN TO BLOW COOLING AIR ACROSS THE EXTERNAL FRAME.
4. EXPLOSION-PROOF - A TOTALLY ENCLOSED MOTOR DESIGNED TO WITHSTAND AN EXPLOSION WITHIN AND TO PREVENT IGNITION OF GAS SURROUNDING IT.

MOTOR AND CONTROL MODIFICATIONS
SECTION 8 
PAGE X-2

50 CYCLE MOTORS
TO PRICE A PUMP WITH A 50 CYCLE MOTOR (STANDARD 50 CYCLE VOLTAGE), USE THE 60 CYCLE PRICE OF THE NEXT HIGHER H.P. AT THE REQUIRED R.P.M. THE OPERATING SPEED AT 50 CYCLES WILL BE 5/6 OF THE 60 CYCLE SPEED. DERATE PERFORMANCE CURVES ACCORDINGLY. STANDARD 50 CYCLE VOLTAGES ARE 190/380V, 200/400V, 208/416V AND 220/440V. FOR OTHER 50 CYCLE VOLTAGES, CONSULT ABC ELECTRIC CORP.

SPLASH-PROOF MOTORS
CURRENT DRIP-PROOF MOTORS INCORPORATE MOST OF THE FEATURES OF THE OLD SPLASH-PROOF DESIGN AND CAN BE USED FOR MOST APPLICATIONS CALLING FOR SPLASH-PROOF HOUSINGS.

POWER CORD AND PLUG
Power cord and plug (3-wire plug with ground) is furnished as standard equipment on 115V motors on the following units: MC-1, MMC-1, MCH and ALTV. To add an 8-Ft. Power cord and plug for 1/4, 1/3 and 1/2 HP motors OPERATING at 230V  (or 115V  on units not enumerated above) add   ---   $135

TOTALLY ENCLOSED AND EXPLOSION-PROOF MOTORS SEE SECTION 8, PAGE X-3

MISCELLANEOUS MODIFICATIONS
CONSULT ABC ELECTRIC CORP FOR MODIFICATIONS SHOWN BELOW, OR FOR OTHER NON-STANDARD FEATURES:
HIGH ALTITUDE MOTORS.
SPECIAL SHAFT EXTENSIONS.
HIGH AMBIENT TEMP  MOTORS.
GUARDED MOTORS, SCREENED OPENINGS.
NON-STANDARD VOLTAGES.
SPACE HEATERS IN MOTORS.
EXTRA LONG LEADS.
TEMPERATURE SENSORS IN WINDINGS.
SPECIAL NAMEPLATES.
STAR-DELTA MOTORS.

FACTORY CHOICE BRANDS
FEDERAL RESERVES THE RIGHT TO FURNISH FACTORY CHOICE BRAND MOTORS AND CONTROLS AS SHOWN BELOW. IF NON-STANDARD BRANDS ARE REQUIRED, ADD THE FOLLOWING PERCENTAGES TO THE LIST PRICES OF THE MOTORS OR CONTROLS:
MAGNETIC STARTERS, COMBINATION STARTERS, D&T PANELS    ---   ADD 40%
FRACTIONAL FRAME MOTORS   ---   ADD 55%
INTEGRAL FRAME MOTORS   ---   ADD 35%

STANDARD VOLTAGES AND SUPPLIERS
STANDARD SUPPLIERS SHOWN ARE FOR GENERAL INFORMATION ONLY AND ARE SUBJECT TO CHANGE WITHOUT NOTICE:

MOTOR OR CONTROL

STD. VOLTAGE

STD. SOURCE

MC-1, MMC-1, ALTV MOTORS

115 OR 230

GENERAL ELEC.

1-PHASE MOTORS (FRACTIONAL FRAME)

115/230

WESTINGHOUSE

3-PHASE MOTORS (FRACTIONAL FRAME)

208/230/460

WESTINGHOUSE

VERTICAL C-FACE (INTEGRAL FRAME)

200 OR 230/460

BALDOR

CLOSE-COUPLED PUMP MOTORS (INTEGRAL FRAME)

208/230/460

MARATHON

STANDARD HORIZONTAL MOTORS FOR FLEXIBLE COUPLING (INTEGRAL FRAME)

200 OR 230/460

MARATHON

VSS SUBMERSIBLE MOTORS

200/400 OR 230/460

RELIANCE

MAGNETIC STARTERS, COMBINATION STARTERS, D & T PANELS

CUTLER - HAMMER

FLOAT SWITCHES, ALTERNATING FLOAT SWITCHES

SQUARE D

SBS AND SP-PR-FA PANELS

CEW WITH CUTLER-HAMMER COMPONENTS

NOTE: STANDARD SOURCE FOR MOTORS SHOWN ABOVE ARE FOR DRIP-PROOF MOTORS. SOURCES FOR TOTALLY ENCLOSED AND EXPLOSION-PROOF MOTORS MAY VARY.