Member of:

 

 

Official website of:

Federal Pump Corp.

                                                                                          Motors, Pumps, Controls, Drives, Hoists
HOME Up one level Feedback Request Quote SEARCH
VCL Prices

CENTRIFUGAL CONDENSATION RETURN UNITS

 

TYPE VCL SECTION 1
CONDENSATION RETURN UNITS PAGE VCL-1
BULLETIN 109 FEBRUARY 2001

LIST PRICES

          Units With Cast Iron Receivers    
          1- Phase 3-Phase Shipp'g Weight  
Unit No.  Sq. Ft. E.D.R. Disch.  Press. Motor H.P. R.P.M Single Duplex Single Duplex Single Duplex Pump Code
VCL-110-2
VCL-120-2
VCL-130-2
VCL-140-2
VCL-150-2
1,000
1,000
1,000
1,000
1,000
10#
20
30
40
50
1/3
1/3
3/4
1
1-1/2
3450
3450
3450
3450
3450
3957
3957
4089
4164
4431
6324
6324
6594
6741
7278
5592
5592
5739
5835
6105
8802
8802
9096
9291
9828
200#
200
200
200
200
330#
330
330
330
330
VCL-50
VCL-50
VCL-75
VCL-100
VCL-150
VCL-210-2
VCL-220-2
VCL-230-2
VCL-240-2
VCL-250-2
2,000
2,000
2,000
2,000
2,000
10
20
30
40
50
1/3
1/3
3/4
1
1-1/2
3450
3450
3450
3450
3450
3957
3957
4089
4164
4431
6324
6324
6594
6741
7278
5592
5592
5739
5835
6105
8802
8802
9096
9291
9828
200
200
200
200
200
330
330
330
330
330
VCL-50
VCL-50
VCL-75
VCL-100
VCL-150
VCL-410-2
VCL-420-2
VCL-430-2
VCL-440-2
VCL-450-2
4,000
4,000
4,000
4,000
4,000
10
20
30
40
50
1/3
1/3
3/4
1
1-1/2
3450
3450
3450
3450
3450
3957
3957
4089
4164
4431
6324
6324
6594
6741
7278
5592
5592
5739
5835
6105
8802
8802
9096
9291
9828
200
200
200
200
200
330
330
330
330
330
VCL-50
VCL-50
VCL-75
VCL-100
VCL-150
VCL-610-2
VCL-620-2
VCL-630-2
VCL-640-2
VCL-650-2
6,000
6,000
6,000
6,000
6,000
10
20
30
40
50
1/3
1/3
3/4
1
1-1/2
3450
3450
3450
3450
3450
3957
3957
4089
4164
4431
6324
6324
6594
6741
7278
5592
5592
5739
5835
6105
8802
8802
9096
9291
9828
200
200
200
200
200
330
330
330
330
330
VCL-50
VCL-50
VCL-75
VCL-100
VCL-150
VCL-810-2
VCL-820-2
VCL-830-2
VCL-840-2
VCL-850-2
8,000
8,000
8,000
8,000
8,000
10
20
30
40
50
1/3
1/3
3/4
1
1-1/2
3450
3450
3450
3450
3450
4443
4443
4578
4653
4920
6324
6324
6594
6741
7278
6069
6069
6216
6312
6582
8802
8802
9096
9291
9828
280
280
280
280
280
330
330
330
330
330
VCL-50
VCL-50
VCL-75
VCL-100
VCL-150
VCL-1010-2
VCL-1020-2
VCL-1030-2
VCL-1040-2
VCL-1050-2
10,000
10,000
10,000
10,000
10,000
10
20
30
40
50
1/3
1/3
3/4
1
1-1/2
3450
3450
3450
3450
3450
4443
4443
4578
4653
4920
6324
6324
6594
6741
7278
6069
6069
6216
6312
6582
8802
8802
9096
9291
9828
280
280
280
280
280
330
330
330
330
330
VCL-50
VCL-50
VCL-75
VCL-100
VCL-150
VCL-1510-2
VCL-1520-2
VCL-1530-2
VCL-1540-2
15,000
15,000
15,000
15,000
10
20
30
40
1/3
1/2
3/4
1
3450
3450
3450
3450
6642
6678
6777
6849
8523
8595
8790
8937
7887
7938
8034
8133
10623
10719
10917
11112
430
430
430
430
480
480
480
480
VCL-50
VCL-50
VCL-75
VCL-100
VCL-2010-2
VCL-2020-2
VCL-2030-2
VCL-2040-2
20,000
20,000
20,000
20,000
10
20
30
40
1/3
3/4
1
1-1/2
3450
3450
3450
3450
6642
6678
6777
6849
8523
8790
8937
9474
7887
7938
8034
8400
10623
10917
11112
11649
430
430
430
430
480
480
480
480
VCL-50
VCL-75
VCL-100
VCL-150
VCL-110-4
VCL-210-4
VCL-410-4
VCL-610-4
VCL-810-4
VCL-1010-4
1,000
2,000
4,000
6,000
8,000
10,000
10
10
10
10
10
10
1/4
1/4
1/4
1/4
1/4
1/4
1750
1750
1750
1750
1750
1750
4116
4116
4116
4116
4602
4602
6642
6642
6642
6642
6642
6642
5616
5616
5616
5616
6093
6093
8853
8853
8853
8853
8853
8853
200
200
200
200
200
200
330
330
330
330
330
330
VCL-150
VCL-150
VCL-150
VCL-150
VCL-150
VCL-150

 

DEDUCTION FOR STEEL RECEIVERS:
Standard units priced above have cast iron receivers. Use the following list price deductions and shipping weight deductions for units to be built with steel receivers:
RECEIVER CAPACITY  LIST PRICE DEDUCTIONS WEIGHT DEDUCTION
10 gallon $1086 50#
15 gallon $1257   80#
30 gallon $2601 100#

VCL PUMP ONLY:
List price shown is for (1) VCL replacement pump only with coupling. The motor is not included. The same list price applies to all VCL pump codes. The standard "PUMP" multipliers apply for this item. (The "PARTS" multipliers do not apply.)
List price   -------------------------------------------------  $1632
Shipping weight   ------------------------------------------   40#

NON-STANDARD RECEIVER SIZES:
To increase the receiver size from the standard size to a larger size, make the following list price and shipping weight additions:

STD. REC. SIZE CHANGE TO LIST ADD WEIGHT ADD
10 gallon 15 gallon $ 477 80#
10 gallon 30 gallon 2295 230
15 gallon 30 gallon 1818 150

TYPE VCL SECTION 1
CONDENSATION RETURN UNITS PAGE VCL-2
BULLETIN 109 FEBRUARY 2001

MOTOR PROTECTION:
All single phase motors have built-in overload protection and, therefore, no magnetic starters are required for these units. Float switches on these units are wired directly to the motors at the factory.

All three phase units are furnished with magnetic starters for motor protection. The magnetic starters are mounted on the unit and factory wired to the float switches and motors.

RECEIVER INLET STRAINER:
2"   -----------------------------------   $234  

 3"   ---------------------------------   $549

GAUGE GLASS:
Water level gauge glass and cocks on receiver   ----------------------------   $162

THERMOMETER:
6" Column type thermometer (range 40-270ºF) for receiver ----------------    $126

MAGNETIC STARTERS:
Mounted wired on single phase units:
Single unit   ----------------------   $936 

Duplex unit   ----------------------   $1854

MANUAL STARTERS:
Mounted and wired on single phase units:

Single unit   ----------------------   $468          

Duplex unit   ---------------------   $918

ALTERNATING FLOAT SWITCH:
One alternating float switch on duplex unit (in lieu of the two standard float switches)   ---------   $315

ALTERNATING AND AUXILIARY FLOAT SWITCHES:
one alternating float switch on duplex unit plus one 2-pole emergency auxiliary float switch (in lieu of the two standard float switches)   -------   $927

ELECTRIC ALTERNATOR:
Automatic electric alternator, in NEMA-1 enclosure, mounted and wired on the unit (Can be furnished only on duplex units with two standard float switches and two magnetic starters)   -----------   $1628

VACUUM-TIGHT MODIFICATIONS:
Altering the unit for use in returning condensation into a system operating under a vacuum: 
Single Unit   -------------------   $810 

Duplex unit   -------------------------   $1620

COLD WATER MAKE-UP VALVE:
All-bronze mechanical float-operated make-up water valve in the receiver when the VCL unit is to act as a boiler feed unit and the VCL pump(s) is to be controlled by a level control switch mounted on the boiler.  The standard float switch(es) are omitted on these units.  Add the letters 'BF' to the unit number (i.e.: VCL-120-2 becomes VCL-120-2BF).

Single unit   ----------------------   no add 

Duplex Unit   -------------------------   $315

OTHER MODIFICATIONS AND ACCESSORIES:

Combination starters, disconnect switches

see VSA pages

Starter modifications

see VSA pages

Discharge pressure gauges

see BFC pages
Lead-lag control  see CCV pages
Single-enclosure duplex control panels see Misc. Section
Non-standard motor and control enclosures & wiring see Misc. Section

Wiring deductions for single phase units 

see CCV pages
Starter mounting and/or wiring deductions for 3-phase units see CCV pages

Manual starters for three phase units

see CCV pages
Additional receiver tappings see CCV pages