Low Inlet Boiler Feed Units
Bulletin
129B
|

|

|
 |
Centrifugal boiler feed pumps |
 |
Heavy steel receivers |
 |
Completely assembled units |
 |
Integral makeup water valve |
 |
Automatic maintenance of boiler water level |
 |
Simplex, Duplex, Triplex and Quadruplex Units |
 |
Special modifications and controls available |
 |
1750 or 3450 RPM operation |
 |
Ratings to 1000 Boiler HP |
 |
Discharge pressures to 125 psig |
 |
For industrial, institutional and residential installations |
|
FEATURES
RECEIVING TANK:
Heavy steel construction, mounted on steel
saddles fitted
with thermometer and gauge glass.
MAKEUP
WATER VALVE:
All-bronze
float actuated valve, flange
mounted in tank head, permits entry of makeup water, when
required, to replace system losses. Complete with strainer
on make-up water connection.
PUMP(S):
Close-coupled, bronze-fitted, centrifugal design,
with
leakless mechanical shaft seal.
MOTOR(S):
Drip-proof ball bearing type close-coupled to pump(s). Single phase motors in fractional H.P.
frame sizes have
built-in thermal overload protection. Single phase motors in integral H.P.
frame sizes, and all 3 phase motors, are furnished with magnetic starters in NEMA 1 general purpose
wallmounting
enclosures. Units are available with 1750 R.P.M. or 3450
R.P.M. motors (see Engineering Selection Table).
UNITS:
Unit is factory assembled. Simplex unit has one
receiving tank,
one makeup valve and one pump and motor. Duplex unit has one receiving tank, one makeup valve, and two
pumps and motors.
Triplex unit has one receiving tank, one makeup valve and three pumps and motors. Quadruplex unit
has one receiving
tank, one makeup valve and four pumps and motors.
OPERATION:
Boiler feed pump(s) is controlled
by a boiler water
level controller mounted on the boiler. These controllers are
usually furnished with integral low water cut-off and alarm switches.
Boiler feed water is taken from the receiver, and if condensate
has been lost in the system, it is automatically replaced
by the makeup valve
MODIFICATIONS
TO STANDARD UNITS
NON-STANDARD
TANK SIZES: Units can be furnished with tank capacities other than shown
in the selection table. Diameters and lengths of receivers can be modified where
required by space conditions. Return inlet height and location can be modified.
GALVANIZING
OF RECEIVER: Hot-dip galvanized inside and outside.
SPECIAL
RECEIVER COATINGS: Special interior and exterior coatings where job
conditions require extra corrosion resistance.
INTERIOR
TANK BAFFLES: Built into tank to prevent air or sludge from entering pump
suction.
SPECIAL
RECEIVER TAPPINGS: Special or additional tappings as required.
MANHOLE:
Manhole and bolted cover for clean-out and inspection.
DRAIN
VALVE: Tank drain connection can be fitted with bronze drain valve.
EXTERNAL
FLOAT CHAMBER MAKEUP VALVE: Mounted on end of receiver with 3-valve
by-pass piping to permit manual and automatic makeup water control. Has built-in
strainer.
SOLENOID
OPERATED MAKEUP VALVE: Furnished with reverse-acting float switch in
receiver to actuate the solenoid valve. Requires electric service for operation
and is furnished with makeup water strainer. Can be furnished with or without
air gap.
CORROSION
INHIBITOR BAR: Magnesium anode bar in the receiver to inhibit electrolytic
corrosion; with drip-hole to indicate when bar has been completely corroded and
requires replacement.
FEED
WATER HEATERS: Perforated brass steam injection pipe operated by
temperature regulating valve with sensor.
SPECIAL
THERMOMETER: Standard column type can be replaced by special thermometers
as specified.
PRESSURE
GAUGES: Pump discharge pressure gauge available.
NON-STANDARD
MOTOR ENCLOSURES: Standard enclosures are drip-proof. Totally enclosed and
explosion-proof enclosures are available.
TRANSFER
SWITCHES: To alternate pump operation or transfer pump-boiler relationship
in multiple-boiler installations.
CONTROL
PANELS: Control components can be mounted on factory-wired wallmounting
or floor-mounting panel, in lieu of individual wall-mounting enclosures.
NON-STANDARD
MOTOR CONTROLS: "Hand-off-Automatic" selector switch, pilot
light and control circuit transformer for motor starters; waterproof or
explosion-proof enclosures for starters; combination magnetic starters and
disconnect switches, plus combination magnetic starters and circuit breakers.
LARGER
UNITS: For ratings in excess of 1000 Boiler H.P. and discharge pressures
up to 125 psi, consult ABC Electric Corp.
STRAINER: Fitted to the return inlet connection of receiver.
CONDENSATION
RETURN UNITS: BFV Units can be furnished as condensation return units by
substituting a float switch in the receiver to operate each pump and removing
the make-up water valve.
SHUT-OFF VALVE FOR PUMP SUCTION: Units can be furnished with butterfly
shut-off valve for each pump suction connection. .
Click
Here for Price List
Click Here for BFV Data
Click Here for Parts Cross-Reference
| Engineering
Selection Table |
Motor HP. |
|
Pump Disch. Size & Type |
| Unit No. |
Boiler HP |
Pump Disch. Press PSIG |
Boiler Evap. GPM |
Pump Cap. GPM |
1750 RPM |
3450 RPM |
Rec. Tank Cap. Gal. |
1750 RPM |
3450 RPM |
BFV-1510
1515
1520
1530
1540
1550
1560
1570
1580 |
15 |
10#
15
20
30
40
50
60
70
80 |
1.04 |
3 |
1/4
1/3
1/2
1
2
3
5
7-1/2
- |
1/3
1/3
1/3
3/4
1
1-1/2
2
3
3 |
26 |
1-1/4
1
1
1-1/2
1-1/2
2
2
2
- |
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1
1
1 |
BFV-3010
3015
3020
3030
3040
3050
3060
3070
3080 |
30 |
10#
15
20
30
40
50
60
70
80 |
2.07 |
6 |
1/4
1/3
1/2
1
2
3
5
7-1/2
- |
1/3
1/3
1/3
3/4
1
1-1/2
2
3
3 |
33 |
1-1/4
1
1
1-1/2
1-1/2
2
2
2
- |
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1
1
1 |
BFV-5010
5015
5020
5030
5040
5050
5060
5070
5080 |
50 |
10#
15
20
30
40
50
60
70
80 |
3.45 |
10 |
1/4
1/3
1/2
1
2
3
5
7-1/2
- |
1/3
1/3
1/3
3/4
1
1-1/2
2
3
3 |
45 |
1-1/4
1
1
1-1/2
1-1/2
2
2
2
- |
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1
1
1 |
BFV-7510
7515
7520
7530
7540
7550
7560
7570
7580 |
75 |
10#
15
20
30
40
50
60
70
80 |
5.18 |
15 |
1/4
1/2
3/4
1
2
3
5
7-1/2
- |
1/3
1/3
1/3
3/4
1
1-1/2
2
3
3 |
100 |
1-1/4
1
1
1-1/2
1-1/2
2
2
2
- |
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1
1
1 |
BFV-10010
10015
10020
10030
10040
10050
10060
10070
10080 |
100 |
10#
15
20
30
40
50
60
70
80 |
6.9 |
20 |
1/4
1/2
3/4
1-1/2
2
3
5
7-1/2
- |
1/3
1/3
1/3
3/4
1
1-1/2
3
3
3 |
100 |
1-1/4
1
1
1-1/2
1-1/2
2
2
2
- |
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1
1
1 |
BFV-15010
15015
15020
15030
15040
15050
15060
15070
15080 |
150 |
10
15
20
30
40
50
60
70
80 |
10.4 |
30 |
1/2
3/4
3/4
1-1/2
3
3
5
7-1/2
- |
1/3
1/2
1/2
3/4
1
2
3
3
5 |
150 |
1
1
1
1-1/2
1-1/2
2
2
2
- |
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/2
1
1
1 |
BFV-20010
20015
20020
20030
20040
20050
20060
20070
20080 |
200 |
10
15
20
30
40
50
60
70
80 |
13.8 |
40 |
1/3
3/4
1
2
3
3
5
7-1/2
- |
1/2
3/4
3/4
1
1-1/2
3
3
5
5 |
220 |
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
2
2
2
- |
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/2
1
1
1 |
BFV-25010
25015
25020
25030
25040
25050
25060
25070
25080 |
250 |
10
15
20
30
40
50
60
70
80 |
17.3 |
50 |
1/2
3/4
1-1/2
2
3
5
5
7-1/2
- |
3/4
3/4
3/4
1
2
3
5
5
5 |
250 |
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
2
2
2
- |
1-1/4
1-1/4
1-1/4
1-1/4
1-1/2
1-1/2
1
1
1 |
BFV-30010
30015
30020
30030
30040
30050
30060
30070
30080 |
300 |
10
15
20
30
40
50
60
70
80 |
20.7 |
60 |
3/4
1
1-1/2
2
3
5
5
7-1/2
- |
3/4
1
1-1/2
2
3
5
5
5
7-1/2 |
315 |
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
2
2
2
- |
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1
1
1-1/2 |
|
BFV-40010
40015
40020
40030
40040
40050
40060
40070
40080
|
400 |
10
15
20
30
40
50
60
70
80 |
27.6 |
80 |
1
1-1/2
2
3
5
5
7-1/2
7-1/2
- |
3/4
1
1-1/2
2
3
5
7-1/2
7-1/2
10 |
390 |
1-1/2
1-1/2
2
1-1/2
2
2
2
2
- |
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2 |
BFV-50010
50015
50020
50030
50040
50050
50060
50070
50080 |
500 |
10
15
20
30
40
50
60
70
80 |
34.5 |
100 |
1
1-1/2
2
3
5
5
7-1/2
10
- |
1
1-1/2
1-1/2
3
5
5
7-1/2
7-1/2
10 |
500 |
2
2
2
1-1/2
2
2
2
2
- |
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2 |
BFV-75010
75015
75020
75030
75040
75050
75060
75070
75080 |
750 |
10
15
20
30
40
50
60
70
80 |
51.8 |
150 |
1-1/2
2
3
5
7-1/2
7-1/2
10
15
- |
3
3
3
5
7-1/2
7-1/2
10
15
15 |
750 |
2
2
2-1/2
2
2-1/2
2
2
2
- |
2-1/2
2-1/2
2
2
2
2
2
2
2 |
BFV-100010
100015
100020
100030
100040
100050
100060
100070
100080 |
1000 |
10
15
20
30
40
50
60
70
80 |
69.0 |
200 |
2
3
5
5
7-1/2
10
15
15
- |
3
3
3
5
7-1/2
10
10
15
15 |
1000 |
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2
2
2
- |
2-1/2
2-1/2
2-1/2
2
2
2
2
2
2 |
| Units
operating at 1750 RPM, add -4 to unit number (Example: BFV-15020-4);
units operating at 3450 RPM, add -2 to unit number (Example: BFV-15020-2). Units are available for discharge pressures higher
than 80 PSIG, to a maximum of 125 PSIG. |


Suggested Specifications for Architects and
Engineers
Furnish and install where indicated on plans, a Type BFV Simplex (or Duplex;
Triplex; Quadruplex) Boiler Feed Unit, as manufactured by Federal Pump Corp.,
Unit No. BFV-_____ sized to provide feed water to _____boiler(s), (each)
developing _____boiler H.P. (Each) pump shall deliver _____G.P.M. at a discharge
pressure of _____PSIG at the pump(s).
Unit shall be factory assembled by the pump manufacturer, including all
required accessories. Pump(s) shall be close-coupled, end-suction,
bronze-fitted, centrifugal type, flanged to suction chamber which shall be
welded onto the receiver shell. Pump(s) shall have mechanical shaft seal and
bronze shaft sleeve and shall be driven by _____H. P., _____phase, _____cycles,
_____volts, _____R.P.M. ball bearing, drip-proof (or totally enclosed;
explosion-proof) motor(s). Single phase motors in fractional H.P. frame sizes
shall have built-in thermal overload protection. Single phase motors in integral
H.P. frame sizes and all three phase motors shall be provided with
across-the-line type magnetic starters in NEMA-1 general purpose (or NEMA-4
Water-tight; NEMA-7 Explosion-proof) wall-mounting enclosure(s).
Receiver shall have a capacity of _____gallons, heavy steel construction,
with gauge glass, thermometer, and connections for low level return inlet, vent
and drain. Makeup water valve, flange-mounted on tank head, shall be of
all-bronze construction, float operated with makeup water strainer.
Furnish and install on (each) boiler a water level controller to
automatically operate the pump(s), with low-water cut-off and alarm switch, plus
alarm bell. Controller shall be equal to McDonnell-Miller No. 150 (for boiler
pressures up to 150 P.S.I.) or No. 94 (for boiler pressures up to 250 P.S.I.).
(Boiler water level controller are not usually furnished by Federal).