Type BFC

BFC Dimensions
BFC Suggested Specs
BFC Parts List

 
Boiler Feed Units

 
Bulletin 127D

 

bullet

Centrifugal boiler feed pumps

bullet

Heavy steel receivers

bullet

Completely assembled units

bullet

Integral makeup water valve

bullet

Automatic maintenance of boiler water level

bullet

Simplex, Duplex, Triplex and Quadruplex Units

bullet

Special modifications and controls available

bullet

1750 or 3450 RPM operation

bullet

Ratings to 1000 Boiler HP

bullet

Discharge pressures to 125 psig

bullet

For industrial, institutional and residential installations

 

FEATURES


RECEIVING TANK:

Heavy steel construction, mounted on steel legs, and fitted with thermometer and gauge glass.

MAKEUP WATER VALVE:

All-bronze float actuated valve, flange mounted in tank head, permits entry of makeup water, when required, to replace system losses. Complete with strainer on make-up water connection.  
PUMP(S)

Close-coupled, bronze-fitted, centrifugal design, with leakless mechanical shaft seal.

MOTOR(S):

Drip-proof ball bearing type close-coupled to pump(s). Single phase motors in fractional H.P. frame sizes have built-in thermal overload protection. Single phase motors in integral H.P. frame sizes, and all 3 phase motors, are furnished with magnetic starters in NEMA 1 general purpose wall­mounting enclosures. Units are available with 1750 R.P.M. or 3450 R.P.M. motors (see Engineering Selection Table).

UNITS:

Unit is factory assembled on single steel base with pump suction piping complete. Simplex unit has one receiving tank, one makeup valve and one pump and motor. Duplex unit has one receiving tank, one makeup valve, and two pumps and motors. Triplex unit has one receiving tank, one makeup valve and three pumps and motors. Quadruplex unit has one receiving tank, one makeup valve and four pumps and motors.

OPERATION

Boiler feed pump(s) is controlled by a boiler water level controller mounted on the boiler. These controllers are usually furnished with integral low water cut-off and alarm switches. Boiler feed water is taken from the receiver, and if condensate has been lost in the system, it is automatically replaced by the makeup valve.



MODIFICATIONS TO STANDARD UNITS

NON-STANDARD TANK SIZES:  Units can be furnished with tank capacities other than shown in the selection table. Diameters and lengths of receivers can be modified where required by space conditions. Return inlet height and location can be modified. 


GALVANIZING OF RECEIVER:  Hot-dip galvanized inside and outside.


SPECIAL RECEIVER COATINGS:  Special interior and exterior coatings where job conditions require extra corrosion resistance.


INTERIOR TANK BAFFLES:  Built into tank to prevent air or sludge from entering pump suction.


SPECIAL RECEIVER TAPPINGS:  Special or additional tappings as required.


MANHOLE: Manhole and bolted cover for clean-out and inspection.


DRAIN VALVE:  Tank drain connection can be fitted with bronze drain valve.


EXTERNAL FLOAT CHAMBER MAKEUP VALVE:  Mounted on end of receiver with 3-valve by-pass piping to permit manual and automatic makeup water control. Has built-in strainer.


SOLENOID OPERATED MAKEUP VALVE:  Furnished with reverse-acting float switch in receiver to actuate the solenoid valve. Requires electric service for operation and is furnished with makeup water strainer. Can be furnished with or without air gap.


CORROSION INHIBITOR BAR:  Magnesium anode bar in the receiver to inhibit electrolytic corrosion, with drip-hole to indicate when bar has been completely corroded and requires replacement.


FEED WATER HEATERS:  Perforated brass steam injection pipe operated by temperature regulating valve with sensor.


SPECIAL THERMOMETER:  Standard column type can be replaced by special thermometers as specified.


PRESSURE GAUGES:  Pressure gauge available for each pump discharge.


NON-STANDARD MOTOR ENCLOSURES:  Standard enclosures are drip-proof. Totally enclosed and explosion-proof enclosures are available.


TRANSFER SWITCHES:  To alternate pump operation or transfer pump-boiler relationship in multiple-boiler installations.


CONTROL PANELS:  Control components can be mounted on factory-wired wall­mounting or floor-mounting panel, in lieu of individual wall-mounting enclosures.


NON-STANDARD MOTOR CONTROLS:  "Hand-off-Automatic" selector switch, pilot light and control circuit transformer for motor starters; waterproof or explosion-proof enclosures for starters; combination magnetic starters and disconnect switches, plus combination magnetic starters and circuit breakers.


FLEXIBLY-COUPLED PUMPS:  Can be substituted for the standard close-coupled pumps.


LARGER UNITS:  For ratings in excess of 1000 Boiler H.P. and discharge pressures up to 125 psi, consult ABC Electric Corp.


STRAINERS:  In pump suction lines or fitted to the return inlet connection of receiver.


CONDENSATION RETURN UNITS:  BFC Units can be furnished as condensation return units by substituting a float switch in the receiver to operate each pump and removing the make-up water valve.


SUCTION GATE VALVE:  Can be added in each pump suction line to isolate pump from tank. 


Click Here for Price List


Click Here for Dimensions

Click Here for Part Cross-Reference

Click Here for Suggested Specifications

 

 

Engineering Selection Table Motor HP.   Pump Disch. Size & Type
Unit No. Boiler HP Pump Disch. Press PSIG Boiler Evap. GPM Pump Cap. GPM 1750 RPM 3450 RPM Rec. Tank Cap. Gal. 1750 RPM 3450 RPM
BFC-1510
1515
1520
1530
1540
1550
1560
1570
1580
15 10#
15
20
30
40
50
60
70
80
1.04 3 1/4
1/3
1/2
1
2
3
5
7-1/2
-
1/3
1/3
1/3
3/4
1
1-1/2
2
3
3
26 1-1/4 CC
1 CG
1 CG
1-1/2 CK
1-1/2 CK
2 CKH
2 CKH
2 CKH
-
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1 CG
1 CG
1 CG
BFC-3010
3015
3020
3030
3040
3050
3060
3070
3080
30 10#
15
20
30
40
50
60
70
80
2.07 6 1/4
1/3
1/2
1
2
3
5
7-1/2
-
1/3
1/3
1/3
3/4
1
1-1/2
2
3
3
33 1-1/4 CC
1 CG
1 CG
1-1/2 CK
1-1/2 CK
2 CKH
2 CKH
2 CKH
-
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1 CG
1 CG
1 CG
BFC-5010
5015
5020
5030
5040
5050
5060
5070
5080
50 10#
15
20
30
40
50
60
70
80
3.45 10 1/4
1/3
1/2
1
2
3
5
7-1/2
-
1/3
1/3
1/3
3/4
1
1-1/2
2
3
3
45 1-1/4 CC
1 CG
1 CG
1-1/2 CK
1-1/2 CK
2 CKH
2 CKH
2 CKH
-
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1 CG
1 CG
1 CG
BFC-7510
7515
7520
7530
7540
7550
7560
7570
7580
75 10#
15
20
30
40
50
60
70
80
5.18 15 1/4
1/2
3/4
1
2
3
5
7-1/2
-
1/3
1/3
1/3
3/4
1
1-1/2
2
3
3
100 1-1/4 CC
1 CG
1 CG
1-1/2 CK
1-1/2 CK
2 CKH
2 CKH
2 CKH
-
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1 CG
1 CG
1 CG
BFC-10010
10015
10020
10030
10040
10050
10060
10070
10080
100 10#
15
20
30
40
50
60
70
80
6.9 20 1/4
1/2
3/4
1-1/2
2
3
5
7-1/2

-
1/3
1/3
1/3
3/4
1
1-1/2
3
3
3
100 1-1/4 CC
1 CG
1 CG
1-1/2 CK
1-1/2 CK
2 CKH
2 CKH
2 CKH
-
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1 CG
1 CG
1 CG
BFC-15010
15015
15020
15030
15040
15050
15060
15070
15080
150 10#
15
20
30
40
50
60
70
80
10.4 30 1/2
3/4
3/4
1-1/2
3
3
5
7-1/2
-
1/3
1/2
1/2
3/4
1
2
3
3
5
150 1 CG
1 CG
1 CG
1-1/2 CK
1-1/2 CK
2 CKH
2 CKH
2 CKH
-
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/2 CG
1 CG
1 CG
1 CG
BFC-20010
20015
20020
20030
20040
20050
20060
20070
20080
200 10#
15
20
30
40
50
60
70
80
13.8 40 1/3
3/4
1
2
3
3
5
7-1/2
-
1/2
3/4
3/4
1
1-1/2
3
3
5
5
220 1-1/2 CG
1-1/2 CG
1-1/2 CG
1-1/2 CK
1-1/2 CK
2 CKH
2 CKH
2 CKH
-
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/2 CG
1-1/2 CG
1 CG
1 CG
1 CG
BFC-25010
25015
25020
25030
25040
25050
25060
25070
25080
250 10#
15
20
30
40
50
60
70
80
17.3 50 1/2
3/4
1-1/2
2
3
5
5
7-1/2
-
3/4
3/4
3/4
1
2
3
5
5
5
250 1-1/2 CG
1-1/2 CG
1-1/2 CG
1-1/2 CK
1-1/2 CK
2 CKH
2 CKH
2 CKH
-
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/4 CC
1-1/2 CG
1-1/2 CG
1 CG
1 CG
1 CG
BFC-30010
30015
30020
30030
30040
30050
30060
30070
30080
300 10#
15
20
30
40
50
60
70
80
20.7 60 3/4
1
1-1/2
2
3
5
5
7-1/2

-
3/4
1
1-1/2
2
3
5
5
5
7-1/2
315 1-1/2 CG
1-1/2 CG
1-1/2 CG
1-1/2 CK
1-1/2 CK
2 CKH
2 CKH
2 CKH
-
1-1/2 CC
1-1/2 CC
1-1/2 CC
1-1/2 CC
1-1/2 CC
1-1/2 CG
1 CG
1 CG
1-1/2 CG
BFC-40010
40015
40020
40030
40040
40050
40060
40070
40080
400 10#
15
20
30
40
50
60
70
80
27.6 80 1
1-1/2
2
3
5
5
7-1/2
7-1/2
-
3/4
1
1-1/2
2
3
5
7-1/2
7-1/2
10
390 1-1/2 CG
1-1/2 CG
2 CG
1-1/2 CK
2 CK
2 CKH
2 CKH
2 CKH
-
1-1/2 CC
1-1/2 CC
1-1/2 CC
1-1/2 CC
1-1/2 CC
1-1/2 CG
1-1/2 CG
1-1/2 CG
1-1/2 CG
BFC-50010
50015
50020
50030
50040
50050
50060
50070
50080
500 10#
15
20
30
40
50
60
70
80
34.5 100 1
1-1/2
2
3
5
5
7-1/2
10
-
1
1-1/2
1-1/2
3
5
5
7-1/2
7-1/2
10
500 2 CG
2 CG
2 CG
1-1/2 CK
2 CK
2 CKH
2 CKH
2 CKH
-
1-1/2 CC
1-1/2 CC
1-1/2 CC
1-1/2 CC
1-1/2 CG
1-1/2 CG
1-1/2 CG
1-1/2 CG
1-1/2 CG
BFC-75010
75015
75020
75030
75040
75050
75060
75070
75080
750 10#
15
20
30
40
50
60
70
80
51.8 150 1-1/2
2
3
5
7-1/2
7-1/2
10
15
-
3
3
3
5
7-1/2
7-1/2
10
15
15
750 2 CG
2 CG
2-1/2 CG
2 CK
2-1/2 CK
2 CKH
2 CKH
2 CKH
-
2-1/2 CG
2-1/2 CG
2 CG
2 CG
2 CG
2 CG
2 CG
2 CG
2 CG
BFC-100010
100015
100020
100030
100040
100050
100060
100070
100080
1000 10#
15
20
30
40
50
60
70
80
69.0 200 2
3
5
5
7-1/2
10
15
15
-
3
3
3
5
7-1/2
10
10
15
15
1000 2-1/2 CG
2-1/2 CG
2-1/2 CK
2-1/2 CK
2-1/2 CK
2 CKH
2 CKH
2 CKH
-
2-1/2 CG
2-1/2 CG
2-1/2 CG
2 CG
2 CG
2 CG
2 CG
2 CG
2 CG
Units operating at 1750 RPM, add -4 to unit number (Example: BFC-15020-4); units operating at 3450 RPM, add -2 to unit number (Example: BFC-15020-2).  Units are available for discharge pressures higher than 80 PSIG, to a maximum of 125 PSIG.

 

 

BOILER FEED UNIT
MAKEUP WATER ASSEMBLY
WITH SOLENOID OPERATED VALVE AND AIR GAP
DATA NO. 127.7