Member of:

 

 

Official website of:

Federal Pump Corp.

                                                                                          Motors, Pumps, Controls, Drives, Hoists
HOME Up one level Feedback Request Quote SEARCH
Type P


Submersible Sump Pumps
 

Bulletin 206C

FEATURES

MOTOR:
Fully submersible motor in cast iron housing with stainless steel shaft. Units operate at 1750 RPM. Single phase motors are available for 115V or 230V operation. (115V only for 1/4 HP units) and have built in overload protection. Three phase motors are available for 1/3 HP and 1/2 HP units, rated for 230V operation and should be provided with magnetic starters.

PUMP:
Close-coupled design with impeller locked firmly to the motor shaft. All units have cast iron pump volutes. Impellers are plastic for 1/4 HP and 1/3 HP units and cast iron for 1/2 HP units. Some units are available in all-bronze construction.

POWER CORD:
Fully sealed waterproof power cord is furnished on all single phase units. The standard cord length is 10-ft. for 1/4 HP units and 20-ft. for 1/3 HP and 1/2 HP units. Longer power cords are available if required.

FLOAT SWITCH:
Automatic operation of the single phase pumps is provided by an integral submersible float switch. For all three phase units and for single phase units where non-standard float travel is required, the float switch is furnished in a separate submersible housing for mounting on the discharge pipe of the pump.

APPLICATION:
Type P submersible sump pumps are ideally suited for a variety of applications including elevator pits, home and industrial building sumps, loading dock areas and effluent pits. Standard-fitted construction is suitable for most applications.

ACCESSORIES:
A variety of accessories are available for Type P submersible sump pumps including magnetic starters, control panels, long-travel float switches, sump basins (cast iron or steel or fiberglass), pit covers and grouting frames for concrete pits and high water alarms. Type P pumps can also be controlled by the Federal Type SBS Submers-a-bulb controllers (see SBS Bulletin 263).

SELECTION TABLE

MODEL

G.P.M.

DISCH. HEAD (FT.)

DISCH. SIZE (INS.)

MOTOR H.P.

11/2P-1/4-4

10

19

1-1/2

1/4

11/2P-1/3-4

10

22

1-1/2

1/3

2P-1/2-4

10

25

2

1/2

11/2P-1/4-4

15

18

1-1/2

1/4

11/2P-1/3-4

15

21

1-1/2

1/3

2P-1/2-4

15

24

2

1/2

11/2P-1/4-4

20

17

1-1/2

1/4

11/2P-1/3-4

20

20

1-1/2

1/3

2P-1/2-4

20

23

2

1/2

11/2P-1/4-4

30

13

1-1/2

1/4

11/2P-1/3-4

30

18

1-1/2

1/3

2P-1/2-4

30

22

2

1/2

11/2P-1/4-4

40

8

1-1/2

1/4

11/2P-1/3-4

40

15

1-1/2

1/3

2P-1/2-4

40

21

2

1/2

11/2P-1/3-4

50

12

1-1/2

1/3

2P-1/2-4

50

20

2

1/2

11/2P-1/3-4

60

10

1-1/2

1/3

2P-1/2-4

60

19

2

1/2

2P-1/2-4

70

18

2

1/2

2P-1/2-4

80

16

2

1/2

2P-1/2-4

90

15

2

1/2

2P-1/2-4

100

13

2

1/2

 

Model Min Sump Dia. (Ins.) Overall Pump Hgt. (Ins.) Disch. Size (Ins.) Cord Lgth, (Ft.) Max. Amb. Temp. Wgt. (Lbs) Std. Float Travel (Ins.)

11/2P-1/4-4

12

10

1-1/2

10

104°F

40

9

11/2P-1/3-4

12

12

1-1/2

20

130°F

40

9

2P-1/2-4

15

18

2

20

130°F

60

9


SUGGESTED SPECIFICATION FOR SINGLE UNIT (1/3 HP & 1/2 HP UNITS)
Furnish and install where shown on plans, a single Type P submersible sump pump unit, as manufactured by Federal Pump Corporation. Pump to have a capacity of ____G.P.M. against a total dynamic head of ____ft. Pump to have ____N.P.T. discharge connection and to be standard-fitted construction with submersible sealed motor, stainless steel
shaft and waterproof power cable. Motor to be ____H.P., 1-ph., 60 cy., ____volts, 1750 RPM, with integral fully submersible float switch, for automatic control of the pump.

Furnish a welded angle iron grouting frame and heavy steel cover equal to Federal Type PF-1, for a concrete pit ___ins. x ___ins. x ___ins, deep. Cover and frame to be treated with corrosion resistant coating and cover to have openings for cable, vent connection and pump removal plate.

SUGGESTED SPECIFICATION FOR DUPLEX UNIT (1/3 HP & 1/2 HP UNITS)
Furnish and install where shown on plans, a duplex Type P submersible sump pump unit, as manufactured by Federal Pump Corporation. Each pump to have a capacity of ____G.P.M. against a total dynamic head of ____ft. Pumps to have
____N.P.T. discharge connections and to be of standard-fitted construction with submersible sealed motor, stainless steel shaft and waterproof power cable. Motors to be ____H.P., ____phase, 60 cycles, ____volts, 1750 RPM. Each pump shall have a fully submersible float switch for mounting on the pump discharge pipe.

Furnish a duplex pump control panel in a single NEMA-1 enclosure, including fusible disconnect switch, magnetic starter and hand-off-automatic selector switch for each motor, and an automatic alternator to alternate the sequence of operation of the two pumps and provide simultaneous operation of the pumps when required.

Furnish a fiberglass (or cast iron or steel) sump basin, ____ins. in diameter x ____ins. deep, with inlet connection as determined by job conditions. The basin shall have a steel cover with required openings for pump removal plates, controls and vent connection, and shall be treated with a corrosion resistant coating.

BASIC UNIT 1/4 HP:
Cast iron construction, plastic impeller, and 10-ft. power cord.

BASIC UNIT 1/3 HP:
Cast iron construction, plastic impeller, and 20-ft. power cord.

BASIC UNIT 1/2 HP:
Cast iron construction, cast iron impeller, and 20-ft. power cord.

MODEL FLOAT SWITCH LIST PRICES APPROX. SHIP'G WGT
1/115 V 1/230 V 3/230 V
1-1/2P-1/4-4 NO $ 915 $  - $  - 40#
1-1/2P-1/4-4 YES 972   -   - 40
1-1/2P-1/3-4 NO 1167 1167   - 50
1-1/2P-1/3-4 YES 1287 1287   - 50
2P-1/2-4 NO 2091 2091 2373 70
2P-1/2-4 YES 2211 2211 3630* 70
*List price for 3-phase unit with float switch includes the pump plus a discharge-pipe-mounted float switch with 22" float rod, but does not include a magnetic starter which must be added separately.

ALL-BRONZE PUMP CONSTRUCTION:
If all-bronze pump construction is required, consult factory.

HIGH TEMPERATURE PUMPS:
The standard maximum ambient temperature ratings for Type P pumps is 104°F for 1/4 HP units and 130°F for 1/3 HP and 1/2 HP units. If special-fitted pumps are required for higher ambient temperatures, consult ABC Electric Corp.

SUBMERSIBLE SWITCH:
Separate submersible float bulb with cable and mounting bracket for mounting on pump discharge pipe (or other mounting arrangement), for actuation of high water alarm or control of duplex pumps through an alternator   ---   $390

OTHER MODIFICATIONS AND ACCESSORIES:
Type D duplex panels          ------   see Section 8
High water alarm bells and panels          ------   see Sec.4, VSA pages
Magnetic starters          ------   see Sec.4, VSA pages
Steel, cast iron & fiberglass sump basins          ------   see Sec.4, VSA pages
Covers & grouting frames for conc. pits          ------   see Sec.4, VSA pages
Export boxing          ------   see Sec.4, VSA pages

DELIVERY LEAD TIMES:
Any modification of the standard pump unit will substantially increase the delivery time.

QUICK-DISCONNECT UNITS:
Type P Submersible Sump Pumps can be furnished with Quick-Disconnect fittings for easy removal from the sump pit. The fittings furnished for each pump include (1) base elbow and QD connection, (1) lift chain and (1) top bracket. The components that are generally furnished by others are: the pump discharge pipe and the pump guide pipes (two guide pipes are required per pump). Guide pipes are 3/4" schedule 40 galvanized steel. The following QD list price addition is to be made to the basic pump list prices shown on Page P-1. The same addition applies for 1-1/2" and 2" discharge pumps.

List price addition per pump (double for duplex)           ------   $1716
Shipping weight addition per pump          ------   100#

QD GUIDE PIPES:
Two guide pipes are required for each pump. Thus, four pipes are required for a duplex pump set. They are generally furnished by the contractor. If they are to be furnished with the pumps, the following applies:

List price per pump per foot of pit depth           ------   $45
Shipping weight per pump per foot of pit depth           ------   10#

Performance Curve

SUGGESTED SPECIFICATION FOR SINGLE UNIT (1/3 HP & 1/2 HP UNITS)

Furnish and install where shown on plans, a single Type P submersible sump pump unit, as manufactured by Federal Pump Corporation. Pump to have a capacity of _____G.P.M. against a total dynamic head of _____ft. Pump to have _____N.P.T. discharge connection and to be standard-fitted construction with submersible sealed motor, stainless steel shaft and waterproof power cable. Motor to be _____H.P., 1-ph., 60 cy., _____volts, 1750 RPM, with integral fully submersible float switch, for automatic control of the pump.

Furnish a welded angle iron grouting frame and heavy steel cover equal to Federal Type PF-1, for a concrete pit _____ins. x _____ins. x _____ins. deep. Cover and frame to be treated with corrosion resistant coating and cover to have openings for cable, vent connection and pump removal plate.

SUGGESTED SPECIFICATION FOR DUPLEX UNIT (1/3 HP & 1/2 HP UNITS)

Furnish and install where shown on plans, a duplex Type P submersible sump pump unit, as manufactured by Federal Pump Corporation. Each pump to have a capacity of _____G.P.M. against a total dynamic head of _____ft. Pumps to have _____N.P.T. discharge connections and to be of standard-fitted construction with submersible sealed motor, stainless steel shaft and waterproof power cable. Motors to be _____H.P., _____phase, 60 cycles, _____volts, 1750 RPM. Each pump shall have a fully submersible float switch for mounting on the pump discharge pipe.

Furnish a duplex pump control panel in a single NEMA-1 enclosure, including fusible disconnect switch, magnetic starter and hand-off-automatic selector switch for each motor, and an automatic alternator to alternate the sequence of operation of the two pumps and provide simultaneous operation of the pumps when required.

Furnish a fiberglass (or cast iron or steel) sump basin, _____ins. in diameter x _____ins. deep, with inlet connection as determined by job conditions. The basin shall have a steel cover with required openings for pump removal plates, controls and vent connection, and shall be treated with a corrosion resistant coating.

TYPE 1-1/2P-QD & 2P-QD
QUICK-DISCONNECT
SUBMERSIBLE SUMP PUMPS
INSTALLATION DRAWING
DATA NO. 206.1

NOTE: This installation drawing applies to all Type P submersible sump pumps with Quick-Disconnect fittings.

Model No. W/O QD fittings Model No. W/ QD fittings
1-1/2P - 1/4-4 1-1/2P -QD- 1/4-4
1-1/2P - 1/3-4 1-1/2P -QD- 1/3-4
2P - 1/2-4 2P -QD- 1/2-4